Felicity IVGM25KHP3G3 25 kVA Hybrid Inverter
The Felicity IVGM25KHP3G3 is a hybrid inverter with specifications as published by the manufacturer.
- Battery Type: LFP (LiFePO4)
- Battery Voltage Range: 160~700Vdc
- Max. Charging Current: 50(A)
Aperçu
The Felicity IVGM25KHP3G3 is a hybrid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVGM25KHP3G3.
Spécifications complètes
Caractéristiques électriques
| Battery Type | LFP (LiFePO4) |
|---|---|
| Battery Voltage Range | 160~700Vdc |
| Max. Charging Current | 50(A) |
| Max. Discharging Current | 50(A) |
| Max. DC Access Power | 50kW |
| Max. DC Input Power | 40kW |
| Max. DC Input Voltage | 1000Vdc |
| Min. DC Input Voltage | 150Vdc |
| Start-up Voltage | 200Vdc |
| Rated DC Input Voltage | 600Vdc |
| MPPT Range | 200~850Vdc |
| Full Load DC Voltage Range | 666-850Vdc |
| PV Input Current | 30+30(A) |
| Max. PV Isc | 39+39(A) |
| No.of Strings Per MPP Tracker | 2+2 |
| Rated AC Input/Output Power | 25kW |
| Max. AC Input/Output Apparent Power | 27.5kVA |
| AC Input/Output Rated Current | 36.3A |
| Max. AC Current | 39.8A |
| Peak Power(off-grid) (W) | 1.5times of |
| Rated AC Voltage | 220/380,230/400 Vac (-20%~+15%) |
| AC Wiring Mode | 3L+N+PE |
| Rated AC Frequency | 50/60 Hz (45~55 Hz/55~65 Hz) |
| THDi | <3% (At |
| Power Factor | 0.8( leading) to 0.8( lagging) |
| DC Injection Current | <0.5% In |
| Monitor Module | WiFi/4G |
Caractéristiques mécaniques
| Net Weight | 41.4KG |
|---|---|
| Gross Weight | 47.4KG |
| Product Dimension | 642*445*237.5MM |
| Package Dimension | 784*563*367MM |
| Installation Style | Wall-mounted |
Caractéristiques environnementales
| Protection Degree | IP66 |
|---|---|
| Operating Temperature Range | -40 to 60°C(>45°C Derating) |
| Humidity | 0~95% (No Condensation) |
Certifications
- IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Produits Connexes


AI100-5048 ESS
- Rated Output Power:5000VA
- Max. Solar Charging Current:100A

Felicity IVAM10048P1G1 10000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60

Felicity IVAM12048P1G1 12000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60
Articles Connexes
Batterie Felicity ne charge pas ? Codes et solutions
Batterie Felicity qui ne charge pas ? Sous 0°C le BMS bloque la charge, une tension sous 57,6 V ne remplit jamais le pack, et les codes C01–C08 font le reste.
Lire: Batterie Felicity ne charge pas ? Codes et solutions →Erreur onduleur Felicity après une coupure de courant ?
Une longue coupure a vidé la batterie, le réseau est revenu instable, et un code s'affiche. Le vrai sens de 04, C02, 27 et des alarmes réseau au retour.
Lire: Erreur onduleur Felicity après une coupure de courant ? →Onduleur Felicity en surchauffe ? Erreur 18 et codes chaleur
L'onduleur coupe l'après-midi ? Erreur 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 et C09 batterie — les codes chaleur officiels Felicity et leurs solutions.
Lire: Onduleur Felicity en surchauffe ? Erreur 18 et codes chaleur →