Three-phase output
220/380 V through 277/480 V, ten grid configurations.

Onduleur hybride triphasé haute tension de 40 kW.
Le Felicity Solar IVGM40KHP3G2 est un onduleur hybride triphasé de 40 kW. Il fonctionne avec une batterie LFP haute tension sur une plage de 160 à 800 Vdc via deux entrées batterie, suit le champ photovoltaïque de 150 à 850 Vdc et dispose d'un boîtier IP65 fonctionnant de -40°C à 60°C avec refroidissement intelligent — prévu pour l'extérieur.
| AC Input/Output Rated Current | 58 A |
|---|---|
| Max. AC Input/Output Current | 47.9A |
| Max. AC Output Power | 44kW |
| Max. Charging Current | 50+50(A) |
| Max. DC Input Voltage | 1000Vdc |
| Max. Discharging Current | 50+50(A) |
| Max. Output Overcurrent Protection (A) | (A) |
| Peak Power (off-grid)(W) | power, 10S |
| Protection surintensité | 192 A |
| Puissance CA max | 44 kW |
| Puissance CA nominale | 40 kW |
| Nombre de MPPT | 4 |
| Plage CC pleine charge | 444~850Vdc |
| Type d'installation | Wall-mounted |
| Module de surveillance | WiFi/GPRS |
| Communication BMS | RS485,CAN |
| Altitude | 3000 m (> 2000 m derating) |
| Plage de température | -40 to 60 °C (> 50 °C derating) |
| Normes CEM | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Catégorie de surtension | OVC II(DC), OVC III(AC) |
| Niveau de protection | TYPE II(DC), TYPE II(AC) |
| Rendement MPPT | 99.90% |
| Rendement européen | 97.00% |
| Rendement max | 97.60% |
| Courant d'injection CC | <0.5% In |
| Mode de câblage CA | 3L+N+PE |
| Passage CA continu max | 200 A |
| Puissance de crête hors réseau | 1.5 time of rated power, 10S |
| Chaînes par MPPT | 2 |
| Tension de démarrage | 180 Vd.c. |
| Nombre d'entrées batterie | 2 |
| Rated AC Output Power | 40kW |
| Max AC Output Power | 44kW |
| AC Output Rated Current | 58A |
| Max. AC Current | 63.8A |
| Max. DC Access Power | 80kW |
| Max. DC Input Power | 64kW |
| Full Load DC Voltage Range | 444~850Vdc |
| PV Input Current | 36+36+36+36 (A) |
| Max. PV Isc | 55+55+55+55 (A) |
| Number of MPP Trackers | 4 |
| Battery Type | LFP (LiFePO4) |
| Battery Voltage Range | 160~800Vdc |
| Max Charging Current | 50+50 A |
| Max Discharging Current | 50+50 A |
| Number of Battery Input | 2 |
| Max DC Input Voltage | 1000Vdc |
| Min. DC Input Voltage | 150Vdc |
| Start-up Voltage | 180Vdc |
| Rated DC Input Voltage | 600Vdc |
| MPPT Range | 150~850Vdc |
| Strings per MPP Tracker | 2 |
| Rated AC Voltage | 110V/190V, 115V/200V, 120V/208V, 127V/220V, 133V/230V, 200V/346V, 220V/380V, 230V/400V, 240V/415V, 277V/480V |
| Rated AC Frequency | 50 / 60 Hz (45~55Hz / 55~65Hz) |
| THDi | <3% at rated power |
| Power Factor | 0.8 leading to 0.8 lagging |
| Net Weight | 87.1 kg |
|---|---|
| Gross Weight | 107.1 kg |
| Product Dimension | 940*582*340 mm |
| Package Dimension | 1114*774*469 mm |
| Protection Degree | IP65 |
|---|---|
| Operating Temperature Range | -40 to 60°C (>50°C derating) |
| Humidity | 0~95% (no condensation) |
| Cooling | Smart Cooling |




Batterie Felicity qui ne charge pas ? Sous 0°C le BMS bloque la charge, une tension sous 57,6 V ne remplit jamais le pack, et les codes C01–C08 font le reste.
Lire: Batterie Felicity ne charge pas ? Codes et solutions →Une longue coupure a vidé la batterie, le réseau est revenu instable, et un code s'affiche. Le vrai sens de 04, C02, 27 et des alarmes réseau au retour.
Lire: Erreur onduleur Felicity après une coupure de courant ? →L'onduleur coupe l'après-midi ? Erreur 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 et C09 batterie — les codes chaleur officiels Felicity et leurs solutions.
Lire: Onduleur Felicity en surchauffe ? Erreur 18 et codes chaleur →Max DC access power is 80kW and max DC input power 64kW, over 4 MPP trackers with two strings each.
A high-voltage LFP pack anywhere from 160 to 800 Vdc, on either of its two battery inputs, charging and discharging at 50 A per input.