Fault

FAULT: LED1=ON, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)

Cell Temperature High.

2 Devices that report this code
FAULT: LED1=ON, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)Cell Temperature High.Fault
Description

Cell pack over-temperature protection has tripped.

Cause

Cells heated above the safe operating temperature (charging range 0-55 degC, discharging range -20-60 degC per spec).

Recommended fix

Stop charging/discharging, let the pack cool, and improve ventilation. if the fault persists at normal ambient, contact the supplier.

Source:Felicitysolar LPBF24200-M LiFePO4 Battery System for Households User Guide.pdf · page 9
FAULT: LED1=ON, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)Cell Temperature High.Fault
Description

Cell-pack over-temperature protection has tripped. Listed in the FAULT row of the LED table on page 7 as 'CELL TEMPERATURE HIGH'.

Cause

Cells heated above the safe operating temperature. Per the section 2.3 spec the working temperature range is Discharge -20 to +65 degC and Charge 0 to +55 degC; this fault trips when cells exceed those limits.

Recommended fix

Stop charging / discharging, let the pack cool, and improve ventilation. if the fault persists at normal ambient temperature, contact the supplier for service (section 1.3 items 3 and 12 — only qualified service persons may open the unit).

Source:Battery Manual LPBF48250 (EN).pdf · page 7

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.