FAULT: LED1=OFF, LED2=ON, LED3=ON, LED4=OFF (Green OFF, Red ON)
Discharging Current High.
FAULT: LED1=OFF, LED2=ON, LED3=ON, LED4=OFF (Green OFF, Red ON)Discharging Current High.Fault
Discharge over-current protection has tripped; output is disabled.
Connected load drew more current than the recommended discharge limit (≤80 A) or sustained the 120 A 15 s peak too long, or a short-circuit on the DC bus.
Remove or reduce the load, check for short circuits on the output wiring, and restart the pack. For loads above 6 kVA install at least 2 packs in parallel.
Felicitysolar LPBF24200-M LiFePO4 Battery System for Households User Guide.pdf · page 9FAULT: LED1=OFF, LED2=ON, LED3=ON, LED4=OFF (Green OFF, Red ON)Discharging Current High.Fault
Discharge over-current protection has tripped; output is disabled. Listed in the FAULT row of the LED table on page 7 as 'DISCHARGING CURRENT HIGH'.
Load drew more current than the recommended discharge limit (recommended <=120 A, MAX 200 A for 15 s per section 2.3) or a short circuit on the DC output. Section 1.3 item 11 warns NEVER to cause AC output / DC input short circuits.
Remove or reduce the load, check the DC output wiring for short circuits, and restart the pack. For loads above 6 kVA install at least 2 packs in parallel (section 1.3 item 9). MAX. Output Power is 10 000 W; recommended output power is 6 000 W (section 2.3).
Battery Manual LPBF48250 (EN).pdf · page 7Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.