Critical

FAULT-LED-CVH

Cell voltage high.

2 Devices that report this code
FAULT-LED-CVHCell voltage high.Critical
Description

FAULT mode indicated by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 OFF: an individual cell voltage exceeds the safe upper limit.

Cause

One or more cells over-voltage; possible cell imbalance or charger overvoltage.

Recommended fix

Stop charging; verify charger/inverter max charge voltage; allow BMS to balance and recover.

Source:LUX-X-48100LG01-Litium-Battery-User-Guide.pdf · page 15
FAULT-LED-CVHCell voltage high.Critical
Description

FAULT mode signalled by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 OFF: an individual cell voltage exceeds the safe upper limit.

Cause

One or more cells over-voltage; possible cell imbalance or charger overvoltage.

Recommended fix

Stop charging; verify charger/inverter max charge voltage; allow BMS to balance and recover.

Source:358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21