FAULT-LED-CVH
Cell voltage high.
FAULT-LED-CVHCell voltage high.Critical
FAULT mode indicated by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 OFF: an individual cell voltage exceeds the safe upper limit.
One or more cells over-voltage; possible cell imbalance or charger overvoltage.
Stop charging; verify charger/inverter max charge voltage; allow BMS to balance and recover.
LUX-X-48100LG01-Litium-Battery-User-Guide.pdf · page 15FAULT-LED-CVHCell voltage high.Critical
FAULT mode signalled by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 OFF: an individual cell voltage exceeds the safe upper limit.
One or more cells over-voltage; possible cell imbalance or charger overvoltage.
Stop charging; verify charger/inverter max charge voltage; allow BMS to balance and recover.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.