Felicity Solar Hybrid Inverters 6-8 kW IVGM6KLP1G1 / IVGM7K6LP1G1 / IVGM8KLP1G1
The IVGM6KLP1G1 is a 6 kW single-phase hybrid inverter whose two MPPT trackers are laid out 2+1 strings for 26+13 A, with 135 A of battery charging and discharging and 28.7 A of maximum output current at 220-230 V.
Models and prices
- IVGM6KLP1G1AED 4,095incl. VAT
- IVGM7K6LP1G1AED 2,350incl. VAT
- IVGM8KLP1G1AED 3,250incl. VAT
Technical Specifications
| Parameter | IVGM6KLP1G1 | IVGM7K6LP1G1 | IVGM8KLP1G1 |
|---|---|---|---|
| Performance & Electrical | |||
| AC Output Voltage | 220-230 V | ||
| AC Rated Output Current | 26.1 A | 33 A | 34.8 A |
| AC Wiring Mode | L+N+PE | ||
| Backup Max Output Current | 40 A | ||
| Backup Rated Output Power | 6 kW | 7.6 kW | 8 kW |
| Battery Inputs | 1 | ||
| Battery Type | Lead-Acid, Li-Ion | ||
| Battery Voltage Range | 40-60 V | ||
| Charge Algorithm | Self-Adaption to BMS | ||
| Grid Frequency Range (50 Hz) | 45-55 Hz | ||
| Grid Frequency Range (60 Hz) | 55-65 Hz | ||
| Grid Regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) | ||
| Ground Fault Current Monitoring | Yes | ||
| MPPT Efficiency | 99.9% | ||
| MPPT Full-Load Voltage Range | 230-425 V | ||
| MPPT Trackers | 2 | ||
| MPPT Voltage Range | 120-425 V | ||
| Max AC Input Current | 40 A | ||
| Max AC Output Power | 6.6 kW | 8.36 kW | 8.8 kW |
| Max AC Pass-Through Current | 40 A | 50 A | 50 A |
| Max Charge/Discharge Power | 6 kW | 7.6 kW | 8 kW |
| Max Charging Current | 135 A | 190 A | 190 A |
| Max Discharging Current | 135 A | 190 A | 190 A |
| Max Efficiency | 97.6% | ||
| Max Output Current | 28.7 A | 36 A | 38.3 A |
| Max PV Input Current | 26+13 A | 26+26 A | 26+26 A |
| Max PV Voltage | 500 V | ||
| Max Recommended PV Power | 9 kW | 11.4 kW | 12 kW |
| Max Short-Circuit Current | 44+17 A | 44+44 A | 44+44 A |
| Nominal AC Input Voltage | 220-230 V | ||
| Nominal Input Frequency | 50/60 Hz | ||
| Output Frequency | 50/60 Hz | ||
| Output Short-Circuit Protection | Yes | ||
| Overload Protection | Yes | ||
| PV Working Voltage Range | 90-500 V | ||
| Phase | Single Phase | ||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Arc Fault Circuit Interrupter (AFCI), Insulation Resistor Detection | ||
| Rated Apparent Output Power | 6 kVA | 7.6 kVA | 8 kVA |
| Rated Output Power | 6 kW | 7.6 kW | 8 kW |
| Rated PV Input Voltage | 380 V | ||
| Start-Up Voltage | 100 V | ||
| Strings per MPPT | 2+1 | 2 | 2 |
| Surge Rating | 2*rated (10s) | ||
| Total Harmonic Distortion | <3% | ||
| Transfer Time | 10 ms | ||
| Build & Interfaces | |||
| BMS Communication | RS485, CAN | ||
| Communication Interface | RS232, RS485 | ||
| Display | LCD, LED | ||
| Gross Weight | 40.5 kg | ||
| Installation Style | Wall-Mounted | ||
| Monitoring Module | WiFi/GPRS | ||
| Net Weight | 33.5 kg | ||
| Package Dimensions | 787 x 547 x 358 mm | ||
| Parallel Capability | 6 | ||
| Safety Standard | IEC 62109-1, IEC 62109-2 | ||
| Topology | Isolated (transformer-based) | ||
| Operating Environment | |||
| Cooling | Smart Cooling | ||
| IP Rating | IP65 | ||
| Operating Temperature Range | -25 to 60 (>45 derating) °C | ||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 6 kW rated with 6.6 kW of maximum AC output power: Rated output power and rated apparent output power are 6 kW and 6 kVA, maximum AC output power is 6.6 kW and maximum charge and discharge power 6 kW, with surge capacity of twice rated power for 10 seconds.
- 9 kW of recommended PV over two asymmetric MPPT trackers: Maximum recommended PV power is 9 kW across two MPPT trackers laid out 2+1 strings, taking 26+13 A of input current and 44+17 A of short-circuit current, tracking 120-425 V from a 100 V start-up, holding full load 230-425 V up to a 500 V maximum PV voltage, at 99.9% MPPT efficiency.
- 135 A of charging and discharging on a 40-60 V bank: Maximum charging current and maximum discharging current are both 135 A into one battery input covering 40-60 V, for Lead-Acid or Li-Ion packs, with a charge algorithm that self-adapts to the BMS over RS485 and CAN.
- 220-230 V output, 26.1 A rated and 28.7 A maximum: AC output is single phase 220-230 V on L+N+PE wiring, rated 26.1 A and 28.7 A at maximum, with 40 A of backup output current, 40 A of AC input and pass-through current, a 10 ms transfer time, THD below 3% and a power factor adjustable from 0.8 leading to 0.8 lagging.
- 97.6% efficiency behind AFCI and GFCI protection: Maximum efficiency is 97.6%, with an arc fault circuit interrupter, GFCI protection, insulation resistor detection, anti-islanding protection and ground fault current monitoring. Certification is to IEC 62109-1 and IEC 62109-2, and grid settings cover VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1 and EN 50549-10.
- 430 x 654 x 243 mm IP65 chassis at 33.5 kg net: The wall-mounted, smart-cooled IP65 unit measures 430 x 654 x 243 mm and weighs 33.5 kg net and 40.5 kg gross in a 787 x 547 x 358 mm carton, runs from -25 to 60 °C with derating above 45 °C, reports over WiFi or GPRS behind an LCD and LED panel, and parallels to 6 units. Warranty: 2 Years.
- Rated 7.6 kW of output power, 7.6 kVA apparent, with a maximum AC output of 8.36 kW and a 36 A maximum output current
- Two MPPT trackers accept 26+26 A across a 120-425 V tracking window, up to 500 V PV and 11.4 kW of recommended array power
- Charges and discharges a 40-60 V Lead-Acid or Li-Ion battery at up to 190 A and 7.6 kW, with RS485 or CAN BMS communication
- 97.6% peak conversion efficiency and 99.9% MPPT efficiency, with total harmonic distortion held below 3%
- 7.6 kW of backup output at 40 A with a 10 ms transfer time, delivered at 220-230 V, 50/60 Hz over an L+N+PE connection
- IP65 enclosure with smart cooling, -25 to 60 °C operation (derating above 45 °C), 33.5 kg net, wall-mounted, up to 6 units in parallel
Frequently Asked Questions
How much solar can the IVGM6KLP1G1 take?
9 kW is the maximum recommended PV power, over two MPPT trackers laid out 2+1 strings. They take 26+13 A of input current and 44+17 A of short-circuit current, track from 120 to 425 V after a 100 V start-up, hold full load from 230 to 425 V around a 380 V rated PV input voltage, and accept up to 500 V, with the PV working range spanning 90-500 V at 99.9% MPPT efficiency.
How fast does the IVGM6KLP1G1 charge a battery?
135 A is both the maximum charging current and the maximum discharging current, into a single battery input covering 40-60 V, for a maximum charge and discharge power of 6 kW. Lead-Acid and Li-Ion packs are supported, and the charge algorithm self-adapts to the BMS over RS485 and CAN.
What does the IVGM6KLP1G1 deliver on the AC side?
6 kW rated output power and 6 kVA rated apparent output power, single phase at 220-230 V on L+N+PE wiring, with 6.6 kW of maximum AC output power. Rated output current is 26.1 A, maximum output current 28.7 A and backup output current 40 A behind the 6 kW backup output, with a 10 ms transfer time, twice rated power for 10 seconds, THD below 3% and 97.6% maximum efficiency. AC input draws up to 40 A and passes 40 A through, at 50/60 Hz across 45-55 Hz and 55-65 Hz windows.
How big is the IVGM6KLP1G1 and what warranty comes with it?
430 x 654 x 243 mm and 33.5 kg net, 40.5 kg gross in a 787 x 547 x 358 mm carton. The wall-mounted, smart-cooled chassis is rated IP65 and runs from -25 to 60 °C with derating above 45 °C, monitored over WiFi or GPRS with RS232 and RS485 interfaces and an LCD and LED panel. Up to 6 units run in parallel, and the warranty is 2 Years.
How much solar can the IVGM7K6LP1G1 take?
11.4 kW is the maximum recommended PV power, shared across 2 MPPT trackers rated 26+26 A. The tracking window is 120-425 V from a 380 V rated PV input, the working range is 90-500 V with a 500 V maximum, start-up begins at 100 V, each MPPT carries 2 strings, and maximum short-circuit current is 44+44 A.
What battery does the IVGM7K6LP1G1 need?
40-60 V is the battery voltage range, on a single battery input. Lead-Acid and Li-Ion packs are both supported and can be charged or discharged at up to 190 A and 7.6 kW, with the charge algorithm self-adapting to the BMS over RS485 or CAN.
How fast does it switch to backup power?
10 ms is the transfer time. Backup rated output is 7.6 kW with a 40 A maximum backup current at 220-230 V and 50/60 Hz, total harmonic distortion stays below 3%, the surge rating is twice rated power for 10 s, and the power factor is adjustable from 0.8 leading to 0.8 lagging.
How is the IVGM7K6LP1G1 installed and what is it certified to?
IP65 is the enclosure rating and installation is wall-mounted. The unit measures 430 x 654 x 243 mm, weighs 33.5 kg net and 40.5 kg gross, works from -25 to 60 °C with derating above 45 °C under smart cooling, is certified to IEC 62109-1 and IEC 62109-2, and carries a 2 Years warranty.
How much solar can I connect to the Felicity Solar IVGM8KLP1G1?
Up to 12 kW of recommended PV power. Two MPPT trackers take two strings each at 26+26 A, run from 120 to 425 V within a 90-500 V working range capped at 500 V maximum PV voltage, start at 100 V and track at 99.9% efficiency.
Which batteries does the IVGM8KLP1G1 support?
40-60 V is the supported battery range, taking Lead-Acid or Li-Ion packs on a single battery input. Charge and discharge each reach 190 A and 8 kW, and the charge algorithm self-adapts to the BMS over RS485 or CAN.