Felicity Solar Hybrid Inverters 14 kW IVGM14KLP3G1
A 14 kW three-phase hybrid inverter delivering 15.4 kVA apparent power, with two MPPT trackers that accept 22.4 kW of PV and battery charge and discharge current up to 260 A.
Models and prices
- IVGM14KLP3G1AED 7,700incl. VAT
Technical Specifications
| Parameter | IVGM14KLP3G1 |
|---|---|
| Performance & Electrical | |
| AC Output Line Voltage | 380-400 V |
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 20.3 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 14 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 389-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 22.3 A |
| Max AC Pass-Through Current | 70 A |
| Max Apparent Power | 15.4 kVA |
| Max Charging Current | 260 A |
| Max Discharging Current | 260 A |
| Max Efficiency | 97.6% |
| Max Output Current | 22.3 A |
| Max Output Overcurrent Protection | 92 A |
| Max PV Input Current | 26+26 A |
| Max PV Input Power | 22.4 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 39+39 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 14 kVA |
| Rated Output Power | 14 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Protection Level (DC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3% |
| Transfer Time | 20 ms |
| Build & Interfaces | |
| BMS Communication | RS485, CAN |
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
| Operating Environment | |
| Cooling | Smart Cooling |
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 14 kW rated output and 15.4 kVA apparent power on a 380-400 V three-phase 3L+N+PE connection
- 22.4 kW maximum PV input across 2 MPPT trackers, 2+2 strings, 160-650 V MPPT window and 800 V maximum PV voltage
- 97.6% maximum efficiency with total harmonic distortion below 3% and a 20 ms transfer time
- 2 battery inputs for 40-60 V Lead-Acid or Li-Ion banks, charging and discharging at up to 260 A
- IP65 enclosure with smart cooling, rated -25°C to 60°C with derating above 45°C
- Certified to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2, with up to 10 units in parallel
Frequently Asked Questions
What is the rated output power of the Felicity IVGM14KLP3G1?
It is rated at 14 kW output power with 14 kVA rated apparent power and 15.4 kVA maximum apparent power. Rated output current is 20.3 A and maximum output current is 22.3 A, on a 220-230 V phase / 380-400 V line three-phase 3L+N+PE connection at 50/60 Hz. Surge rating is 2x rated for 10 seconds.
How much solar PV can the IVGM14KLP3G1 accept?
Up to 22.4 kW of PV input across 2 MPPT trackers with 2+2 strings. Maximum PV voltage is 800 V, the MPPT operating window is 160-650 V, the full-load MPPT range is 389-800 V and rated PV input voltage is 550 V. Maximum PV input current is 26+26 A, maximum short-circuit current 39+39 A, and start-up voltage 160 V.
Which batteries work with the IVGM14KLP3G1, and at what current?
It has 2 battery inputs for Lead-Acid or Li-Ion banks in a 40-60 V range, with maximum charging and discharging current of 260 A each way. The charge algorithm self-adapts to the battery BMS, which communicates over RS485 or CAN; RS232 and RS485 are available as general communication interfaces, and monitoring is by WiFi or 4G module.
What are the dimensions and operating temperature of the IVGM14KLP3G1?
The product measures 750 x 450 x 268 mm and weighs 48.7 kg net, 60.2 kg gross; packed dimensions are 889 x 566 x 397 mm. It is IP65 rated with smart cooling and operates from -25°C to 60°C, derating above 45°C.