Felicity Solar Off-Grid Inverters 3 kW IVEM3024

The IVEM3024 is a 24 V off-grid inverter of 9.1 kg that delivers a 230 V pure sine wave regulated within 5%, charges at 100 A from solar or utility, and rides an input as low as 90 V.

Models Covered: IVEM3024

Manufacturer: Felicity Solar

Application: The Felicity Solar IVEM3024 is a 3 kW single-phase off-grid solar inverter built around a 24 V battery bank, delivering 3 kVA of apparent power as a 230 V pure sine wave, taking up to 4 kW of PV on one MPPT tracker and charging at 100 A from solar or the utility. Battery voltage is followed from 21 V to 31.5 V in three stages, boost constant current, boost constant voltage at 28.2 V and float at 27 V, across AGM, Flooded, Li-Ion and Self-Defined profiles reported over RS485. The single tracker starts at 125 V, works from 120 to 500 V on one string and takes 15 A up to a 500 V maximum PV voltage. Utility input runs 90-280 V in appliance mode and 170-280 V in UPS mode, passing 40 A through even with no battery fitted, transferring in 50 ms and holding twice rated power for 5 seconds so motors start. Efficiency is 93% at best and above 95% in line mode. The air-cooled IP21 case is 395 x 295 x 129 mm at 9.1 kg net, rated 0-55 °C. We are an authorised Felicity Solar distributor and supply the IVEM3024 from our own stock.

Models and prices

Technical Specifications

Technical Specifications
ParameterIVEM3024
Performance & Electrical
AC Output Voltage230 V
AC Wiring ModeL+N+PE
Backup Rated Output Power3 kW
Battery Inputs1
Battery TypeAGM, Flooded, Li-Ion, Self-Defined
Battery Voltage Range21-31.5 V
Bulk Charging Voltage28.2 V
Charge AlgorithmThree-Stage: Boost CC, Boost CV, Float
Float Charging Voltage27 V
High Frequency Disconnect65 Hz
High Frequency Reconnect63 Hz
High Line Disconnect Voltage280 V
High Line Reconnect Voltage270 V
Input Voltage Range90-280 V
Input Voltage Range (Appliance Mode)90-280 V
Input Voltage Range (UPS Mode)170-280 V
Line Mode Efficiency>95%
Low Frequency Disconnect40 Hz
Low Line Disconnect (Appliance Mode)90 V
Low Line Disconnect (UPS Mode)170 V
Low Line Reconnect (Appliance Mode)100 V
Low Line Reconnect (UPS Mode)180 V
MPPT Trackers1
MPPT Voltage Range120-500 V
Max AC Charge Current100 A
Max AC Input Voltage280 V
Max AC Pass-Through Current40 A
Max Charging Current100 A
Max Efficiency93%
Max PV Input Current15 A
Max PV Input Power4 kW
Max PV Voltage500 V
Max Solar Charging Current100 A
Motor Start CapableYes
Nominal AC Input Voltage230 V
Nominal DC Input Voltage24 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Output Voltage Regulation5%
Output Voltage WaveformPure Sine Wave
Overload ProtectionYes
Overload Trip Time (>105% Load)10.5 s
Overload Trip Time (>150% Load)5.5 s
PV Working Voltage Range120-500 V
Pass-Through Without BatteryYes
PhaseSingle Phase
ProtectionOverload Protection, Over Temperature Protection, Short Circuit Protection
Rated Apparent Output Power3 kVA
Rated Output Power3 kW
Start-Up Voltage125 V
Strings per MPPT1
Surge Rating2*rated (5s)
Transfer Time50 ms
Build & Interfaces
BMS CommunicationRS485
DisplayLCD
Gross Weight10.8 kg
Installation StyleWall-Mounted
Monitoring ModuleBuilt-In WiFi
Net Weight9.1 kg
Package Dimensions472 x 372 x 202 mm
Parallel CapabilityNo
Safety StandardIEC 62109-1, IEC 62109-2, IEC 63027
TopologyHigh-Frequency
Operating Environment
CoolingIntelligent Air Cooling
IP RatingIP21
Operating Temperature Range0-55 °C
Storage Temperature-15 to 60 °C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Felicity Solar Systems: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • 24 V bank followed from 21 V to 31.5 V in three stages: Nominal DC input voltage is 24 V, with the battery followed across 21-31.5 V through boost constant current, boost constant voltage at 28.2 V and float at 27 V, for AGM, Flooded, Li-Ion and Self-Defined profiles on one battery input reporting over RS485.
  • 4 kW of PV on one 120-500 V MPPT tracker: Maximum PV input power is 4 kW on a single MPPT tracker carrying one string, taking 15 A of input current up to a 500 V maximum PV voltage, tracking from 120 to 500 V after a 125 V start-up.
  • 3 kW and 3 kVA at 230 V, regulated within 5%: Rated output power is 3 kW and rated apparent output power 3 kVA, single phase at 230 V on L+N+PE wiring, 50/60 Hz, as a pure sine wave regulated within 5%, with twice rated power for 5 seconds and motor starting supported.
  • 90-280 V input and 40 A of pass-through without a battery: Utility input is accepted from 90 to 280 V in appliance mode and 170 to 280 V in UPS mode, reconnecting at 100 V and 180 V respectively, with 40 A of AC pass-through that works with no battery fitted and a 50 ms transfer time.
  • 93% maximum efficiency, above 95% in line mode: Maximum efficiency is 93% and line-mode efficiency exceeds 95%. Overload trips after 10.5 s above 105% load and 5.5 s above 150%, alongside over temperature and short circuit protection, with certification to IEC 62109-1, IEC 62109-2 and IEC 63027.
  • 395 x 295 x 129 mm at 9.1 kg net, rated 0-55 °C: The wall-mounted, intelligently air-cooled IP21 case measures 395 x 295 x 129 mm and weighs 9.1 kg net and 10.8 kg gross in a 472 x 372 x 202 mm carton, operates from 0 to 55 °C and stores from -15 to 60 °C, with built-in WiFi and an LCD panel. This model does not parallel. Warranty: 2 Years.

Frequently Asked Questions

What battery bank does the IVEM3024 need?

24 V nominal, followed from 21 V to 31.5 V on one battery input. Charging is three-stage, boost constant current then boost constant voltage at 28.2 V then float at 27 V, at up to 100 A from solar or the utility, across AGM, Flooded, Li-Ion and Self-Defined profiles, with the BMS reporting over RS485.

How much solar can the IVEM3024 take?

4 kW is the maximum PV input power, on one MPPT tracker carrying a single string. It draws up to 15 A, starts tracking at 125 V, works from 120 to 500 V and accepts up to 500 V of PV voltage.

Will the IVEM3024 keep loads running from the grid if the battery is disconnected?

Yes, pass-through works without a battery fitted, at up to 40 A. Utility input is accepted from 90 to 280 V in appliance mode and from 170 to 280 V in UPS mode, reconnecting at 100 V and 180 V, with a 50 ms transfer time and line-mode efficiency above 95%.

How hot can the IVEM3024 run and what warranty does it carry?

0 to 55 °C in operation and -15 to 60 °C in storage, in an intelligently air-cooled IP21 case of 395 x 295 x 129 mm and 9.1 kg net, 10.8 kg gross. Maximum efficiency is 93%, certification is to IEC 62109-1, IEC 62109-2 and IEC 63027, and the warranty is 2 Years.