Felicity Solar Off-Grid Inverters 3 kW IVEM3024
The IVEM3024 is a 24 V off-grid inverter of 9.1 kg that delivers a 230 V pure sine wave regulated within 5%, charges at 100 A from solar or utility, and rides an input as low as 90 V.
Models and prices
- IVEM3024AED 1,290incl. VAT
Technical Specifications
| Parameter | IVEM3024 |
|---|---|
| Performance & Electrical | |
| AC Output Voltage | 230 V |
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 3 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 21-31.5 V |
| Bulk Charging Voltage | 28.2 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 27 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (Appliance Mode) | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Line Mode Efficiency | >95% |
| Low Frequency Disconnect | 40 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 120-500 V |
| Max AC Charge Current | 100 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 40 A |
| Max Charging Current | 100 A |
| Max Efficiency | 93% |
| Max PV Input Current | 15 A |
| Max PV Input Power | 4 kW |
| Max PV Voltage | 500 V |
| Max Solar Charging Current | 100 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 24 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5% |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10.5 s |
| Overload Trip Time (>150% Load) | 5.5 s |
| PV Working Voltage Range | 120-500 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 3 kVA |
| Rated Output Power | 3 kW |
| Start-Up Voltage | 125 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 50 ms |
| Build & Interfaces | |
| BMS Communication | RS485 |
| Display | LCD |
| Gross Weight | 10.8 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | Built-In WiFi |
| Net Weight | 9.1 kg |
| Package Dimensions | 472 x 372 x 202 mm |
| Parallel Capability | No |
| Safety Standard | IEC 62109-1, IEC 62109-2, IEC 63027 |
| Topology | High-Frequency |
| Operating Environment | |
| Cooling | Intelligent Air Cooling |
| IP Rating | IP21 |
| Operating Temperature Range | 0-55 °C |
| Storage Temperature | -15 to 60 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 24 V bank followed from 21 V to 31.5 V in three stages: Nominal DC input voltage is 24 V, with the battery followed across 21-31.5 V through boost constant current, boost constant voltage at 28.2 V and float at 27 V, for AGM, Flooded, Li-Ion and Self-Defined profiles on one battery input reporting over RS485.
- 4 kW of PV on one 120-500 V MPPT tracker: Maximum PV input power is 4 kW on a single MPPT tracker carrying one string, taking 15 A of input current up to a 500 V maximum PV voltage, tracking from 120 to 500 V after a 125 V start-up.
- 3 kW and 3 kVA at 230 V, regulated within 5%: Rated output power is 3 kW and rated apparent output power 3 kVA, single phase at 230 V on L+N+PE wiring, 50/60 Hz, as a pure sine wave regulated within 5%, with twice rated power for 5 seconds and motor starting supported.
- 90-280 V input and 40 A of pass-through without a battery: Utility input is accepted from 90 to 280 V in appliance mode and 170 to 280 V in UPS mode, reconnecting at 100 V and 180 V respectively, with 40 A of AC pass-through that works with no battery fitted and a 50 ms transfer time.
- 93% maximum efficiency, above 95% in line mode: Maximum efficiency is 93% and line-mode efficiency exceeds 95%. Overload trips after 10.5 s above 105% load and 5.5 s above 150%, alongside over temperature and short circuit protection, with certification to IEC 62109-1, IEC 62109-2 and IEC 63027.
- 395 x 295 x 129 mm at 9.1 kg net, rated 0-55 °C: The wall-mounted, intelligently air-cooled IP21 case measures 395 x 295 x 129 mm and weighs 9.1 kg net and 10.8 kg gross in a 472 x 372 x 202 mm carton, operates from 0 to 55 °C and stores from -15 to 60 °C, with built-in WiFi and an LCD panel. This model does not parallel. Warranty: 2 Years.
Frequently Asked Questions
What battery bank does the IVEM3024 need?
24 V nominal, followed from 21 V to 31.5 V on one battery input. Charging is three-stage, boost constant current then boost constant voltage at 28.2 V then float at 27 V, at up to 100 A from solar or the utility, across AGM, Flooded, Li-Ion and Self-Defined profiles, with the BMS reporting over RS485.
How much solar can the IVEM3024 take?
4 kW is the maximum PV input power, on one MPPT tracker carrying a single string. It draws up to 15 A, starts tracking at 125 V, works from 120 to 500 V and accepts up to 500 V of PV voltage.
Will the IVEM3024 keep loads running from the grid if the battery is disconnected?
Yes, pass-through works without a battery fitted, at up to 40 A. Utility input is accepted from 90 to 280 V in appliance mode and from 170 to 280 V in UPS mode, reconnecting at 100 V and 180 V, with a 50 ms transfer time and line-mode efficiency above 95%.
How hot can the IVEM3024 run and what warranty does it carry?
0 to 55 °C in operation and -15 to 60 °C in storage, in an intelligently air-cooled IP21 case of 395 x 295 x 129 mm and 9.1 kg net, 10.8 kg gross. Maximum efficiency is 93%, certification is to IEC 62109-1, IEC 62109-2 and IEC 63027, and the warranty is 2 Years.