Felicity Solar Gel Batteries G12V100/G12V65/G12V70AH
A 12 V gel block from Felicity Solar rated 100 Ah, or 1.2 kWh, built from six cells in a 330 × 171 × 218 mm case that weighs 31.5 kg.
Models and prices
Technical Specifications
| Parameter | G12V100AH | G12V65AH | G12V70AH |
|---|---|---|---|
| Performance & Electrical | |||
| Battery Type | Gel | ||
| Cut-Off Voltage | 9.6-10.5 V | ||
| Cycle Service Voltage | 14.4-14.6 V | ||
| Float Charging Voltage | 13.6-13.8 V | ||
| Internal Resistance | 5 mΩ | 6 mΩ | 5.8 mΩ |
| Max Charging Current | 30 A | 22.5 A | 23.5 A |
| Max Charging Voltage | 14.6 V | ||
| Max Discharge Current | 1000 A | 650 A | 700 A |
| Nominal Capacity | 100 Ah | 65 Ah | 70 Ah |
| Nominal Energy | 1.2 kWh | 0.78 kWh | 0.84 kWh |
| Nominal Voltage | 12 V | ||
| Voltage per Unit | 12 V | ||
| Self-Discharge per Month | <3 %/month | ||
| Build & Interfaces | |||
| Capacity Rating Basis | 10hr-rate to 1.8V per cell @25°C | ||
| Cells per Unit | 6 | ||
| Operating Environment | |||
| Charging Temperature Range | 0-50 °C | ||
| Discharging Temperature Range | -20 to 60 °C | ||
| Optimal Operating Temperature | 20-30 °C | ||
| Storage Temperature Range | -20 to 60 °C | ||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 1.2 kWh of stored energy: 100 Ah at a nominal 12 V, rated at the 10-hour rate down to 1.8 V per cell at 25 °C.
- 5 mΩ internal resistance: The G12V100AH is measured at 5 mΩ, with a peak discharge current of 1000 A.
- 30 A maximum charging current: Charging voltage is capped at 14.6 V, with float charging held between 13.6 V and 13.8 V.
- 9.6 V to 10.5 V cut-off band: Cyclic service voltage runs from 14.4 V to 14.6 V on this 12 V block.
- 31.5 kg in a 330 × 171 × 218 mm case: Six cells in one sealed gel case, 330 mm wide, 171 mm high and 218 mm deep.
- Charging from 0 °C to 50 °C: Discharge and storage both run from -20 °C to 60 °C, with 20 °C to 30 °C the optimal band.
- 0.78 kWh of nominal energy: 65 Ah at a nominal 12 V gives the G12V65AH 0.78 kWh of stored energy.
- 22.5 A maximum charging current: Charge at up to 22.5 A, with a 14.6 V maximum charging voltage and a 13.6-13.8 V float.
- 650 A maximum discharge current: Peak discharge reaches 650 A, and the cut-off voltage is 9.6-10.5 V.
- 6 mΩ internal resistance: Internal resistance is measured at 6 mΩ across the 6 cells of the unit.
- Charges 0-50 °C, discharges -20 to 60 °C: Storage runs from -20 to 60 °C, with 20-30 °C the optimal operating temperature.
- 16 kg at 350 × 166 × 175 mm: Self-discharge stays under 3% per month; capacity is rated 10hr-rate to 1.8V per cell @25°C. Warranty: 2 Years.
Frequently Asked Questions
How much energy does the G12V100AH store?
1.2 kWh. The G12V100AH is rated 100 Ah at a nominal 12 V, measured at the 10-hour rate down to 1.8 V per cell at 25 °C, across six cells in one sealed gel block.
What is the maximum charging current for the G12V100AH?
30 A. Charging voltage is capped at 14.6 V, cyclic service runs 14.4 V to 14.6 V, float charging holds between 13.6 V and 13.8 V, and the maximum discharge current is 1000 A.
How much does the G12V100AH weigh and what size is it?
31.5 kg. The case measures 330 mm wide, 171 mm high and 218 mm deep, and holds six cells.
What temperature range can the G12V100AH work in?
0 °C to 50 °C for charging. Discharging and storage both run from -20 °C to 60 °C, the optimal operating band is 20 °C to 30 °C, and the cut-off band is 9.6 V to 10.5 V.
How much energy does the G12V65AH store?
0.78 kWh — the G12V65AH is rated 65 Ah at a nominal 12 V, and that capacity is measured on the 10hr-rate to 1.8V per cell @25°C basis.
What charging current and voltage should I set for the G12V65AH?
22.5 A is the maximum charging current. Set a maximum charging voltage of 14.6 V, 14.4-14.6 V for cycle service and 13.6-13.8 V for float.
How much current can the G12V65AH deliver on discharge?
650 A is the maximum discharge current, with an internal resistance of 6 mΩ and a cut-off voltage of 9.6-10.5 V.
What temperature range does the G12V65AH work in?
0-50 °C for charging and -20 to 60 °C for discharging, with storage also at -20 to 60 °C and 20-30 °C as the optimal operating temperature.
How much energy does the G12V70AH store?
0.84 kWh — that is 70 Ah at a nominal 12 V, rated at the 10-hour rate down to 1.8 V per cell at 25°C.
What is the maximum charging current for the G12V70AH?
23.5 A is the maximum charging current. Keep the charge controller at or below it, cap charging voltage at 14.6 V, and float at 13.6-13.8 V.