Felicity Solar Lithium Batteries FLA48500TG2
Rated for 12,500W of continuous power and a 500A surge, the FLA48500TG2 is a 25kWh LiFePO4 pack in a narrow 570 x 250 x 980mm cabinet weighing 186.5 kg.
Models and prices
- FLA48500TG2AED 1,630incl. VAT
Technical Specifications
| Parameter | FLA48500TG2 |
|---|---|
| Battery Module | |
| Nominal Energy | 25kWh |
| Nominal Voltage | 51.2V |
| Operating Voltage | 44.8-57.6V |
| Max. Continuous Charge/Discharge Current | 250A |
| Peak Charge/Discharge Current (15s) | 500A |
| Max. Charge/Discharge Power | 12,500W |
| Scalability | Max. 15 pcs in Parallel(375kWh) |
| Depth of Discharge (DOD) | ≥95% |
| Cycle Life | >6000 Cycles (25°C±2°C,0.5C/0.5C,90%DOD, 70%EOL) |
| Product Weight | 186.5KG |
| Package Weight | 219.5KG |
| Product Dimension | 570X250X980MM |
| Package Dimension | 1135X690X465MM ME |
| Battery Type | LiFePO4 |
| Communication | RS485/CAN |
| Display Type | LCD+LED |
| Installation | Floor Mounted |
| Protection Degree | IP21 |
| Charging Temperature Range | 0°C~+55°C |
| Discharging Temperature Range | -20°C~+55°C |
| Protection | Built-in Smart BMS, Breaker, Fuse |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 12,500W of continuous charge and discharge power, equal to 250A on the 51.2V bus
- 500A peak charge/discharge current for 15 seconds on the 51.2V bus
- More than 6000 cycles published with its test conditions (25°C±2°C, 0.5C/0.5C, 90%DOD, 70%EOL); depth of discharge is rated separately at ≥95%
- 25kWh of nominal energy in a 570 x 250 x 980mm body only 250mm deep
- 186.5 kg unit weight against 219.5 kg once packed for transport
- Charging from 0°C to +55°C and discharging from -20°C to +55°C, behind IP21 protection
Frequently Asked Questions
What continuous power does the FLA48500TG2 handle?
12,500W of continuous charge and discharge power, which is 250A of continuous current at the 51.2V nominal bus voltage.
What surge can the FLA48500TG2 take?
500A for 15 seconds is the peak charge/discharge current, against 250A of continuous current.
How is the FLA48500TG2 cycle life measured?
More than 6000 cycles, published together with its test conditions (25°C±2°C, 0.5C/0.5C, 90%DOD, 70%EOL). The ≥95% depth of discharge is a different measurement altogether.
How much room does the FLA48500TG2 need?
570 x 250 x 980mm, a depth of only 250mm, at 186.5 kg for the unit and 219.5 kg once packed. Warranty is 5 Years.