FLB48314TG1

Batterie26 codes
20 Défaut 6 Avertissement
C05Charging Overcurrent Protection.Défaut
Description

Charging current reached the trigger value and lasted for 15 seconds. Battery enters fault mode, disabling both charging input and discharging output.

Source:Felicity-FLB48314TG1-Manual.pdf
C06Discharging Overcurrent Protection.Défaut
Description

Discharging current reached the trigger value and lasted for 15 seconds. Battery enters fault mode, disabling both charging input and discharging output.

Source:Felicity-FLB48314TG1-Manual.pdf
CASE-OVERHEATBattery Pack Case Overheating (Abnormal).Avertissement
Description

Surface temperature of case rises abnormally (exceeding normal heat range), accompanied by unusual noises or smells. Note: Some case warmth during normal operation is expected due to MOSFET heat dissipation through the case.

Correction recommandée

Stop using the battery pack immediately and contact professional technicians for inspection and maintenance. Do not attempt to disassemble or handle yourself. Ensure proper ventilation around the case during use.

Source:Felicity-FLB48314TG1-Manual.pdf
CHG-INCOMPLETEBattery Does Not Fully Charge.Avertissement
Description

Charging voltage set on the inverter is too low.

Correction recommandée

Set charging voltage on inverter according to recommended value in battery manual (Max. Charging Voltage: 57.6V; Floating Charging Voltage: 57.6V).

Source:Felicity-FLB48314TG1-Manual.pdf
CHG-NOT-PROGRESSINGBattery Indicates Charging But SOC Does Not Change.Avertissement
Description

Ambient temperature is too low, preventing the battery from charging.

Correction recommandée

Charge the battery within the temperature range specified in the manual (Charging temperature: 0 C to +55 C).

Source:Felicity-FLB48314TG1-Manual.pdf
COMM-FAULTUnable to Communicate with Inverter.Défaut
Description

Wrong communication cable used, or battery DIP switch settings are incorrect.

Correction recommandée

Before connecting battery to inverter, set battery DIP switches correctly per the DIP switch table. After setting DIP switches, restart the battery to activate the DIP, then use correct communication cable.

Source:Felicity-FLB48314TG1-Manual.pdf
FUSE-BLOWNFuse Blown (Overcurrent).Défaut
Description

Battery experienced overcurrent causing the external fuse to blow.

Correction recommandée

Step 1: Use Phillips-head screwdriver to remove screws from fuse cover. Step 2: Open fuse cover, remove old fuse, replace with the new one (spare fuse provided). Step 3: Reattach fuse cover and secure. Non-professionals are not allowed to open this cover.

Source:Felicity-FLB48314TG1-Manual.pdf
Green LED Flash, Red LED OFF, all SOC LEDs OFFLow Power.Avertissement
Description

Battery in low power state. Charge battery as soon as possible. Recharge within 18 hours after full discharge or over-discharge protection triggered.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1 Flash (Power/Running Green LED ON, Red LED OFF)Low SOC Warning.Avertissement
Description

State of Charge below 10% (default threshold). LED1 flashes during Stand By, Normal, or Discharge modes.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=OFF, LED2=OFF, LED3=OFF, LED4=ONBMS Temperature Low.Défaut
Description

Battery Management System (BMS) temperature fell below the lower protection threshold.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=OFF, LED2=OFF, LED3=ON, LED4=OFFCell Voltage Low.Défaut
Description

Voltage of any battery cell fell below the rated protection value during discharging. Over-discharging protection activated.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=OFF, LED2=ON, LED3=OFF, LED4=OFFBattery Voltage Low.Défaut
Description

Total battery pack voltage fell below the rated/protection value. Over-discharge protection activated; system stops supplying power externally.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=OFF, LED2=ON, LED3=OFF, LED4=ONCell Temperature Low.Défaut
Description

Battery cell temperature fell below lower protection threshold. Cell cannot be charged below 0 C.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=OFF, LED2=ON, LED3=ON, LED4=OFFDischarging Current High.Défaut
Description

Discharging current exceeded protection threshold. See also fault code C06 for discharging overcurrent (15-second trigger).

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=OFF, LED3=OFF, LED4=OFFBattery Voltage High.Défaut
Description

Total battery pack voltage exceeded the rated/protection value. Indicated by red Power/Running Status LED with LED1 ON only.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=OFF, LED3=OFF, LED4=ONCell Temperature High.Défaut
Description

Battery cell temperature exceeded upper protection threshold (operating range Charge: 0 to +55 C; Discharge: -20 to +55 C).

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=OFF, LED3=ON, LED4=OFFCharging Current High.Défaut
Description

Charging current exceeded protection threshold. See also fault code C05 for charging overcurrent (15-second trigger).

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=ON, LED3=OFF, LED4=OFFCell Voltage High.Défaut
Description

Voltage of any single cell reached the over-voltage protection value during charging. Charging stopped until cells return to rated range.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=ON, LED3=OFF, LED4=ONCurrent Sensor Abnormal.Défaut
Description

Internal current sensor reading abnormal/out of expected range. Indicates BMS sensor fault.

Source:Felicity-FLB48314TG1-Manual.pdf
LED1=ON, LED2=ON, LED3=ON, LED4=OFFBMS Temperature High.Défaut
Description

Battery Management System (BMS) temperature exceeded the upper protection threshold. May relate to MOSFET heat dissipation through the case.

Source:Felicity-FLB48314TG1-Manual.pdf
OUTPUT-CUTOFF-CURRENTHigh Current Charging/Discharging Causes Output Cutoff.Défaut
Description

Charging and discharging current set on the inverter is too high.

Correction recommandée

Set charging and discharging current on inverter according to recommended values in battery manual (Recommend Charge/Discharge Current: 80A; Max continuous: 160A).

Source:Felicity-FLB48314TG1-Manual.pdf
OUTPUT-INTERRUPTBattery Output Interrupted Due to High Current.Défaut
Description

Charging and discharging current settings on the inverter are too high during charging and discharging operations.

Correction recommandée

Set charging and discharging current on inverter according to recommendations in battery manual.

Source:Felicity-FLB48314TG1-Manual.pdf
OVP-CHGOver Voltage Protection in Charging.Défautprotection
Description

During charging, total voltage of battery pack is higher than rated value or voltage of any single cell reaches protection value. System stops charging.

Correction recommandée

Protection automatically clears when total voltage or all cells return to rated range.

Source:Felicity-FLB48314TG1-Manual.pdf
PARALLEL-DATA-MISSINGParallel Battery Data Missing or Incorrect.Défaut
Description

When multiple batteries are connected in parallel, parallel connection of the batteries is not set up correctly.

Correction recommandée

1) Check the communication cables between the batteries. 2) Check whether the battery DIP switches are set in the correct sequence.

Source:Felicity-FLB48314TG1-Manual.pdf
SOC-INACCURATEInaccurate SOC Display.Avertissement
Description

Battery SOC has not been calibrated.

Correction recommandée

SOC will automatically calibrate after one full charge cycle. Discharge battery to 0%, then charge to 100%. Battery should be fully charged at least once a month.

Source:Felicity-FLB48314TG1-Manual.pdf
UVP-DCHGLow Voltage / Over-Discharge Protection in Discharging.Défautprotection
Description

Voltage of any battery cell or total voltage falls below rated protection value during discharging. Over-discharging protection activated; battery stops supplying power externally.

Correction recommandée

Protection released once voltage of each cell returns to rated range. Recharge within 18 hours.

Source:Felicity-FLB48314TG1-Manual.pdf

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.