Défaut
1 Appareils signalant ce codeFAULT (RED ON, LED1=ON, LED2=ON, LED3=ON, LED4=OFF)
BMS TEMPERATURE HIGH.
FAULT (RED ON, LED1=ON, LED2=ON, LED3=ON, LED4=OFF)BMS TEMPERATURE HIGH.Défaut
Cause
BMS internal (MOSFET / control board) temperature exceeded the upper protection threshold.
Correction recommandée
Check the ambient temperature and cooling space around the unit (per section 8.3 ambient must be 0°C–45°C). Allow the BMS to cool. The fault will self-clear once temperature returns to range. if the fault persists, contact the local distributor.
Source: