Felicity MJS Solar Solutions

Felicity IVPS10048P2G1/IVPS3524P1G1-LV/IVPS5048P1G1-LV/IVPS7548P2G1

Discover the Felicity Solar IVPS10048P2G1 Inverter with 3500VA output, 2800W power, and 24V voltage. Reliable protection features included.

Models Covered: IVPS10048P2G1, IVPS3524P1G1-LV, IVPS5048P1G1-LV, IVPS7548P2G1

Manufacturer: Shenzhen Felicity Solar Technology Co., Ltd.

Application: Introducing the Felicity Solar IVPS3-5-10KVA Inverter, a robust solution for your energy needs. With a rated output power of 3500VA and 2800W, this inverter ensures efficient energy conversion and reliable performance. Designed with overcurrent protection, it guarantees safety and durability.

Technical Specifications

Technical Specifications
Parameter IVPS10048P2G1IVPS3524P1G1-LVIVPS5048P1G1-LVIVPS7548P2G1
Additional Specifications
Battery 0₁
Power 0₁
BMS communication 24V model(default 27.0V) bm5 6 bmS
Capable of Starting Electric Yes
Max. Bypass Overload Current 30A AC63A
Output split-phase system, make sure no "PAL", 3P1, 3P2O2. For parallel system in single phase, make sure noFor supporting three-phase system, make sure no
Output Frequency 50Hz
Output voltage 25.0V to 31.5V. Increment of240V24V model(28.8V default)OPY QC 240V
Power derating 216-06 221
Terminal Connection HOT1-HOT2L-NL-NHOT1-HOT2
Nominal Input Voltage 220Vac120Vac120Vac220Vac
Low Line Re-connect AC Input Range 180±7Vac (UPS) / 100±7Vac (APL)95±3Vac (UPS) / 85±3Vac (APL)95±3Vac (UPS) / 85±3Vac (APL)180±7Vac (UPS) / 100±7Vac (APL)
High Line Re-connect 270±7Vac135±3Vac135±3Vac270±7Vac
Nominal Input Frequency 50Hz/60Hz
Low Line Frequency Disconnect 40±1Hz
Low Line Frequency Re-connect 42±1Hz
High Line Frequency Disconnect 65±1Hz
High Line Frequency Re-connect 63±1Hz
Line Mode Output Waveform Synchronize with input voltage
Pass Through Without Battery No
Overcurrent Protector (grid) 63A50A63A63A
Split-Phase Output Voltage 110/120Vac±5% (HOT1-N or HOT2-N)110/120Vac±5% (HOT1-N OR HOT2-N)110/120Vac±5% (HOT1-N OR HOT2-N)110/120Vac±5% (HOT1-N or HOT2-N)
Inverter Over-Load Protection (SMPS load) 5s@≥150% load; 10s@105%~150% load
Capable of Starting Electric Motor Yes
Output Short Circuit Protection YesYesAir switch protectionYes
Min DC Starting Voltage 46V23V46V46V
Lithium Charging Voltage (max) 61.0V31.5V61.0V61.0V
Product Dimension 584x420x195mm440x391x195mm494x420x195mm494x420x195mm
Gross Weight 67.7 kg30.8 kg35.05 kg38.2 kg
Input Voltage Range 90-280Vac80-140Vac90-280Vac90-280Vac
Electrical Data
Efficiency (Line mode) ≥95%
Max AC Input Voltage 280Vrms140Vrms140Vrms280Vrms
Max Charge Current 80A40A50A60A
Nominal Output Frequency (Hz) 50±0.3Hz / 60±0.3Hz (adjustable)
Rated Output Power 50.0
Rated Output Power (VA) 10000VA3500VA5000VA7500VA
Rated Output Power (W) 8000W2800W4000W6000W
Over-Charge Protection YES
DC Input
Nominal DC Input Voltage 48V24V48V48V
Electrical Characteristics
Input Voltage Waveform Sinusoidal (utility or generator)
Low Line Disconnect 170±7Vac (UPS) / 90±7Vac (APL)90±3Vac (UPS) / 80±3Vac (APL)90±3Vac (UPS) / 80±3Vac (APL)170±7Vac (UPS) / 90±7Vac (APL)
High Line Disconnect 280±7Vac140±3Vac140±3Vac280±7Vac
Over-Load Protection Air switch protectionOvercurrent protectorAir switch protectionAir switch protection
Transfer Time (AC to DC) 15ms (typical)
Transfer Time (DC to AC) 15ms (typical) / 30ms (special)
Input Voltage Range (utility charge) 90-280Vac80-140Vac80-140Vac90-280Vac
Charge Current Regulation 0-80A0-40A0-50A0-60A
Charger Short Circuit 63A50A63A63A
Output Voltage Waveform Pure sine wave
Surge Rating 20000VA for 5 seconds7000VA for 5 seconds10000VA for 5 seconds15000VA for 5 seconds
Low Battery Recovery 47Vdc (load < 50%) / 46Vdc (load ≥ 50%)23.5Vdc (load < 50%) / 23Vdc (load ≥ 50%)47Vdc (load < 50%) / 46Vdc (load ≥ 50%)47Vdc (load < 50%) / 46Vdc (load ≥ 50%)
Low DC Input Shut-down 43Vdc (load < 50%) / 42Vdc (load ≥ 50%)21.5Vdc (load < 50%) / 21Vdc (load ≥ 50%)43Vdc (load < 50%) / 42Vdc (load ≥ 50%)43Vdc (load < 50%) / 42Vdc (load ≥ 50%)
High DC Input Recovery 62Vdc±0.4V31Vdc±0.4V62Vdc±0.4V62Vdc±0.4V
Boost Charging Voltage (AGM) 57.6V28.8V57.6V57.6V
Float Charging Voltage (AGM) 54.4V27.2V54.4V54.4V
Boost Charging Voltage (Flooded) 58.4V29.2V58.4V58.4V
Float Charging Voltage (Flooded) 55.2V27.6V55.2V55.2V
Self-Defined Charging Voltage (max) 61.0V31.5V61.0V61.0V
Over-Load Protection (Smps Load) Air switch protectionOvercurrent protectorAir switch protectionAir switch protection
AC Output
Nominal Output Voltage 220/240Vac±5% (HOT1-HOT2)110/120/127Vac±5% (L-N)110/120/127Vac±5% (L-N)220/240Vac±5% (HOT1-HOT2)
Output Voltage Regulation ±5%rms
Peak Efficiency 90%
Mechanical Data
Package Dimension 670x470x355mm552x508x290mm607x540x290mm607x540x290mm
Operating Conditions
Operating Temperature 0°C~40°C
Storage Temperature -15°C~60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Sudan

Market Sudan
Grid authority / regulator Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum
Quotation currency SDG
Support hours timezone Africa/Khartoum
Delivery & installation coverage Khartoum, Omdurman, Port Sudan, Kassala, Nyala

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Bypass charging function: Bypass charging function
  • High charging current: High charging current
  • Wide range of AC: input voltage
  • Battery self-defined settings: Battery self-defined settings
  • Intelligent adjustment of over-discharge: voltage
  • Comprehensive protection features: Comprehensive protection features

Frequently Asked Questions

What are the main performance specifications of the IVPS3-5-10KVA inverter?

The IVPS3-5-10KVA inverter has a rated output power of 3500VA and 2800W. It operates with a nominal input and output voltage of 24V and achieves an efficiency of >=95% in line mode.

Is the IVPS3-5-10KVA inverter compatible with generators?

Yes, the IVPS3-5-10KVA inverter is compatible with generators as it accepts a sinusoidal input voltage waveform from utility or generator sources.

What are the physical specifications of the IVPS3-5-10KVA inverter?

The specific dimensions and weight of the IVPS3-5-10KVA inverter are not provided in the key specifications. Please refer to the product manual for detailed physical specifications.

What are the installation requirements for the IVPS3-5-10KVA inverter?

The inverter requires a nominal input voltage of 24V and an input voltage range of 80-140Vac. Ensure proper ventilation and adherence to safety guidelines during installation.