Felicity IVPS10048P2G1/IVPS3524P1G1-LV/IVPS5048P1G1-LV/IVPS7548P2G1
Discover the Felicity Solar IVPS10048P2G1 Inverter with 3500VA output, 2800W power, and 24V voltage. Reliable protection features included.
Technical Specifications
| Parameter | IVPS10048P2G1 | IVPS3524P1G1-LV | IVPS5048P1G1-LV | IVPS7548P2G1 |
|---|---|---|---|---|
| Additional Specifications | ||||
| Battery | 0₁ | |||
| Power | 0₁ | |||
| BMS communication | 24V model(default 27.0V) bm5 6 bmS | |||
| Capable of Starting Electric | Yes | |||
| Max. Bypass Overload Current | 30A AC63A | |||
| Output | split-phase system, make sure no "PAL", 3P1, 3P2 | O | 2. For parallel system in single phase, make sure no | For supporting three-phase system, make sure no |
| Output Frequency | 50Hz | |||
| Output voltage | 25.0V to 31.5V. Increment of | 240V | 24V model(28.8V default) | OPY QC 240V |
| Power derating | 216-06 221 | |||
| Terminal Connection | HOT1-HOT2 | L-N | L-N | HOT1-HOT2 |
| Nominal Input Voltage | 220Vac | 120Vac | 120Vac | 220Vac |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) | 95±3Vac (UPS) / 85±3Vac (APL) | 95±3Vac (UPS) / 85±3Vac (APL) | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Re-connect | 270±7Vac | 135±3Vac | 135±3Vac | 270±7Vac |
| Max AC Input Voltage | 280Vrms | 140Vrms | 140Vrms | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz | |||
| Low Line Frequency Disconnect | 40±1Hz | |||
| Low Line Frequency Re-connect | 42±1Hz | |||
| High Line Frequency Disconnect | 65±1Hz | |||
| High Line Frequency Re-connect | 63±1Hz | |||
| Line Mode Output Waveform | Synchronize with input voltage | |||
| Pass Through Without Battery | No | |||
| Overcurrent Protector (grid) | 63A | 50A | 63A | 63A |
| Split-Phase Output Voltage | 110/120Vac±5% (HOT1-N or HOT2-N) | 110/120Vac±5% (HOT1-N OR HOT2-N) | 110/120Vac±5% (HOT1-N OR HOT2-N) | 110/120Vac±5% (HOT1-N or HOT2-N) |
| Inverter Over-Load Protection (SMPS load) | 5s@≥150% load; 10s@105%~150% load | |||
| Capable of Starting Electric Motor | Yes | |||
| Output Short Circuit Protection | Yes | Yes | Air switch protection | Yes |
| Min DC Starting Voltage | 46V | 23V | 46V | 46V |
| Lithium Charging Voltage (max) | 61.0V | 31.5V | 61.0V | 61.0V |
| Product Dimension | 584x420x195mm | 440x391x195mm | 494x420x195mm | 494x420x195mm |
| Gross Weight | 67.7 kg | 30.8 kg | 35.05 kg | 38.2 kg |
| Input Voltage Range | 90-280Vac | 80-140Vac | 90-280Vac | 90-280Vac |
| Electrical Data | ||||
| Efficiency (Line mode) | ≥95% | |||
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) | |||
| Rated Output Power | 50.0 | |||
| Rated Output Power (VA) | 10000VA | 3500VA | 5000VA | 7500VA |
| Rated Output Power (W) | 8000W | 2800W | 4000W | 6000W |
| Over-Charge Protection | YES | |||
| DC Input | ||||
| Nominal DC Input Voltage | 48V | 24V | 48V | 48V |
| Electrical Characteristics | ||||
| Input Voltage Waveform | Sinusoidal (utility or generator) | |||
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) | 90±3Vac (UPS) / 80±3Vac (APL) | 90±3Vac (UPS) / 80±3Vac (APL) | 170±7Vac (UPS) / 90±7Vac (APL) |
| High Line Disconnect | 280±7Vac | 140±3Vac | 140±3Vac | 280±7Vac |
| Over-Load Protection | Air switch protection | Overcurrent protector | Air switch protection | Air switch protection |
| Transfer Time (AC to DC) | 15ms (typical) | |||
| Transfer Time (DC to AC) | 15ms (typical) / 30ms (special) | |||
| Input Voltage Range (utility charge) | 90-280Vac | 80-140Vac | 80-140Vac | 90-280Vac |
| Max Charge Current | 80A | 40A | 50A | 60A |
| Charge Current Regulation | 0-80A | 0-40A | 0-50A | 0-60A |
| Charger Short Circuit | 63A | 50A | 63A | 63A |
| Output Voltage Waveform | Pure sine wave | |||
| Surge Rating | 20000VA for 5 seconds | 7000VA for 5 seconds | 10000VA for 5 seconds | 15000VA for 5 seconds |
| Low Battery Recovery | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) | 23.5Vdc (load < 50%) / 23Vdc (load ≥ 50%) | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) |
| Low DC Input Shut-down | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) | 21.5Vdc (load < 50%) / 21Vdc (load ≥ 50%) | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) |
| High DC Input Recovery | 62Vdc±0.4V | 31Vdc±0.4V | 62Vdc±0.4V | 62Vdc±0.4V |
| Boost Charging Voltage (AGM) | 57.6V | 28.8V | 57.6V | 57.6V |
| Float Charging Voltage (AGM) | 54.4V | 27.2V | 54.4V | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V | 29.2V | 58.4V | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V | 27.6V | 55.2V | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V | 31.5V | 61.0V | 61.0V |
| Over-Load Protection (Smps Load) | Air switch protection | Overcurrent protector | Air switch protection | Air switch protection |
| AC Output | ||||
| Nominal Output Voltage | 220/240Vac±5% (HOT1-HOT2) | 110/120/127Vac±5% (L-N) | 110/120/127Vac±5% (L-N) | 220/240Vac±5% (HOT1-HOT2) |
| Output Voltage Regulation | ±5%rms | |||
| Peak Efficiency | 90% | |||
| Mechanical Data | ||||
| Package Dimension | 670x470x355mm | 552x508x290mm | 607x540x290mm | 607x540x290mm |
| Operating Conditions | ||||
| Operating Temperature | 0°C~40°C | |||
| Storage Temperature | -15°C~60°C | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Jordan
| Market | Jordan |
| Grid authority / regulator | EMRC Jordan |
| Quotation currency | JOD |
| Support hours timezone | Asia/Amman |
| Delivery & installation coverage | Amman, Zarqa, Irbid |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Jordan that is EMRC Jordan. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Bypass charging function: Bypass charging function
- High charging current: High charging current
- Wide range of AC: input voltage
- Battery self-defined settings: Battery self-defined settings
- Intelligent adjustment of over-discharge: voltage
- Comprehensive protection features: Comprehensive protection features
Frequently Asked Questions
What are the main performance specifications of the IVPS3-5-10KVA inverter?
The IVPS3-5-10KVA inverter has a rated output power of 3500VA and 2800W. It operates with a nominal input and output voltage of 24V and achieves an efficiency of >=95% in line mode.
Is the IVPS3-5-10KVA inverter compatible with generators?
Yes, the IVPS3-5-10KVA inverter is compatible with generators as it accepts a sinusoidal input voltage waveform from utility or generator sources.
What are the physical specifications of the IVPS3-5-10KVA inverter?
The specific dimensions and weight of the IVPS3-5-10KVA inverter are not provided in the key specifications. Please refer to the product manual for detailed physical specifications.
What are the installation requirements for the IVPS3-5-10KVA inverter?
The inverter requires a nominal input voltage of 24V and an input voltage range of 80-140Vac. Ensure proper ventilation and adherence to safety guidelines during installation.