FL-OPzV-1000AH-2V
- Voltage Per Unit:2V
- Capacity:1000Ah @10hr-rate to 1.80V per cell @25°C

The Felicity FLA48100 is a lifepo4 battery pack with 5.12kWh of usable storage, a 51.2V nominal bus, 6000 Cycles (25°C±2°C,0.5C/0.5C,90% DOD, 70%EOL) rated.
The Felicity FLA48100 is a lifepo4 battery pack with 5.12kWh of usable storage, a 51.2V nominal bus, 6000 Cycles (25°C±2°C,0.5C/0.5C,90% DOD, 70%EOL) rated. Every figure on this page is taken from the manufacturer's datasheet for the FLA48100.
| Battery Type | LiFePO4 |
|---|---|
| Nominal Energy | 5.12kWh |
| Nominal Voltage | 51.2V |
| Operating Voltage | 44.8-57.6V |
| Recommend Charge/Discharge Power | <5,000W |
| Maximum Charge/Discharge Current(15s) | 150A |
| Maximum Charge/Discharge Power(15s) | 7,500W |
| Scalability | Max. 15 pcs in Parallel(76.8kWh) |
| Depth of Discharge (DOD) | ≥95% |
| Protection | Built-in smart BMS, Breaker, Fuse |
| Communication | RS485/CAN |
| Cycle Life | 6000 Cycles (25°C±2°C,0.5C/0.5C,90% DOD, 70%EOL) |
| Installation | Wall-Mounted / Floor-Mounted |
|---|---|
| Product Weight | 48KG |
| Package Weight | 55KG |
| Product Dimension | 663X400X178MM |
| Package Dimension | 782X522X262MM |
| Protection Degree | IP21 |
|---|




Batterie Felicity qui ne charge pas ? Sous 0°C le BMS bloque la charge, une tension sous 57,6 V ne remplit jamais le pack, et les codes C01–C08 font le reste.
Lire: Batterie Felicity ne charge pas ? Codes et solutions →Une longue coupure a vidé la batterie, le réseau est revenu instable, et un code s'affiche. Le vrai sens de 04, C02, 27 et des alarmes réseau au retour.
Lire: Erreur onduleur Felicity après une coupure de courant ? →L'onduleur coupe l'après-midi ? Erreur 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 et C09 batterie — les codes chaleur officiels Felicity et leurs solutions.