Défaut

FAULT (RED ON, LED1=OFF, LED2=ON, LED3=OFF, LED4=ON)

CELL TEMPERATURE LOW.

1 Appareils signalant ce code
FAULT (RED ON, LED1=OFF, LED2=ON, LED3=OFF, LED4=ON)CELL TEMPERATURE LOW.Défaut
Cause

An individual cell temperature fell below the lower protection threshold (charge: below 0°C; discharge: below -20°C).

Correction recommandée

Warm the environment until cells are within the operating range (Charge: 0°C–55°C, Discharge: -20°C–55°C). The fault will self-clear once temperature normalises. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12