Felicity MJS Solar Solutions

Felicity IVPS2512/IVPS2524/IVPS3524/IVPS5024

2,500 VA / 2,000 W at 12 V off-grid solar inverter with a built-in utility charger.

Models Covered: IVPS2512, IVPS2524, IVPS3524, IVPS5024

Manufacturer: Shenzhen Felicity Solar Technology Co., Ltd.

Application: The Felicity Solar IVPS2512 is an off-grid inverter-charger rated at 2,500 VA / 2,000 W at 12 V. It produces a pure sine wave at 220 Vac, transfers between utility and battery in about 15 ms, and carries a three-stage utility charger with AGM, flooded and self-defined battery profiles. It surges to twice rated power for five seconds, so motor loads start without tripping it.

Technical Specifications

Technical Specifications
Parameter IVPS2512IVPS2524IVPS3524IVPS5024
Additional Specifications
Capable of Starting Electric Yes
Input Voltage Range 90-280Vac
Nominal Input Voltage 220Vac
Low Line Re-connect AC Input Range 180±7Vac (UPS) / 100±7Vac (APL)
High Line Re-connect 270±7Vac
Nominal Input Frequency 50Hz/60Hz
Low Line Frequency Disconnect 40±1Hz
Low Line Frequency Re-connect 42±1Hz
High Line Frequency Disconnect 65±1Hz
High Line Frequency Re-connect 63±1Hz
Pass Through Without Battery No
Over Charge Protection Yes
Capable of Starting Electric Motor Yes
Output Short Circuit Protection Yes
Electrical Data
Efficiency (Line mode) ≥95% (rated R load, battery fully charged)
Max AC Input Voltage 280Vrms
Max Bypass Overload Current AC 30AAC 30AAC 30AAC 63A
Electrical Characteristics
Over-Load Protection (Smps Load) Air switch protectionAir switch protectionAir switch protection5s@≥150% load; 10s@105%~150% load
Input Voltage Waveform Sinusoidal (utility or generator)
Low Line Disconnect 170±7Vac (UPS) / 90±7Vac (APL)
High Line Disconnect 280±7Vac
Transfer Time (AC to DC) 15ms (typical)
Transfer Time (DC to AC) 15ms (typical)
Input Voltage Range (utility charge) 90~280Vac
Max Charging Current (Utility + Solar) 40A
Charge Current Regulation 0A~40A0A~40A0A~40A0A~50A
Charger Short Circuit AC 30AAC 30AAC 30AAC 63A
Output Voltage Waveform Pure sine wave
Over-Load Protection 5s@≥150% load; 10s@105%~150% load SMPS load
Surge Rating 5000VA for 5 seconds5000VA for 5 seconds7000VA for 5 seconds10000VA for 5 seconds
Cold Start Voltage 11.5V23V23V23V
Low Battery Recovery 11.75V (load < 50%) / 11.5V (load ≥ 50%)23.5V (load < 50%) / 23V (load ≥ 50%)23.5V (load < 50%) / 23V (load ≥ 50%)23.5V (load < 50%) / 23V (load ≥ 50%)
Low DC Input Shut-down 10.75V (load < 50%) / 10.5V (load ≥ 50%)21.5V (load < 50%) / 21V (load ≥ 50%)21.5V (load < 50%) / 21V (load ≥ 50%)21.5V (load < 50%) / 21V (load ≥ 50%)
High DC Input Recovery 15.5±0.4V31.0±0.4V31.0±0.4V31.0±0.4V
Boost Charging Voltage (AGM) 14.4V28.8V28.8V28.8V
Float Charging Voltage (AGM) 13.6V27.2V27.2V27.2V
Boost Charging Voltage (Flooded) 14.6V29.2V29.2V29.2V
Float Charging Voltage (Flooded) 13.8V27.6V27.6V27.6V
Self-Defined Charging Voltage (max) 16V31.5V31.5V31.5V
Max Charge Current 40A40A50A
AC Output
Rated Output Power (VA) 2500VA2500VA3500VA5000VA
Rated Output Power (W) 2000W2000W2800W4000W
Nominal Output Voltage 220Vac±5%
Nominal Output Frequency (Hz) 50±0.3Hz / 60±0.3Hz (adjustable)
Output Voltage Regulation ±5%rms
Peak Efficiency 90%
DC Input
Nominal DC Input Voltage 12V24V24V24V
Mechanical Data
Package Dimension 552x408x290mm552x408x290mm552x408x295mm607x540x290mm
Operating Conditions
Operating Temperature 0°C ~ 40°C0°C ~ 40°C0°C ~ 40°C0°C-40°C
Storage Temperature -15°C ~ 60°C-15°C ~ 60°C-15°C ~ 60°C-15°C~60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Pure sine wave: 220 Vac output, safe for motors and electronics.
  • 2× surge for 5 seconds: Starts pumps, fridges and power tools.
  • 15 ms transfer: Switches between grid and battery fast enough for a PC.
  • Bypass charging function: Bypass charging function
  • High charging current: High charging current
  • Wide range of AC: input voltage
  • Battery self-defined settings: Battery self-defined settings
  • 50/60HZ compatible: 50/60HZ compatible
  • Intelligent adjustment of over-discharge: voltage

Frequently Asked Questions

What battery bank does the IVPS2512 need?

12V nominal. The model code says so directly: the last two digits are the battery voltage.

How fast can the IVPS2512 charge from the grid?

Its utility charger is rated 40A, adjustable from zero.

Does the IVPS2512 have a solar input?

No. The IVPS series charges from the utility only; pair it with an external MPPT charge controller for solar, or choose the IVPM series, whose datasheet lists a built-in MPPT as an option.

What battery bank does the IVPS2524 need?

24V nominal. The model code says so directly: the last two digits are the battery voltage.

What are the main performance specifications of the IVPS/IVPM Series inverter?

The IVPS/IVPM Series inverter has a rated output power of 2500VA and 2000W. It operates at a nominal output voltage of 220Vac and a frequency of 50±0.3Hz or 60±0.3Hz, which is adjustable. The inverter boasts a peak efficiency of 90%.

Is the IVPS/IVPM Series inverter compatible with different battery types?

The IVPS/IVPM Series inverter is specifically designed to work with AGM battery types, ensuring optimal performance and longevity.

What are the physical specifications of the IVPS/IVPM Series inverter?

The inverter has package dimensions of 552x408x290mm. It is designed to be compact and efficient, although the exact weight and IP rating are not specified in the provided details.

What are the installation requirements for the IVPS/IVPM Series inverter?

The inverter should be installed in an environment with an operating temperature range of 0°C to 40°C. It is important to ensure proper ventilation and adherence to the manufacturer's installation guidelines.