Felicity IVDM4224P1G3 4.2 kW Off-Grid Inverter
The Felicity IVDM4224P1G3 is an off-grid inverter with specifications as published by the manufacturer.
- Battery Type: Lead-acid or Lithium-ion
- Battery Voltage Range(V): 20-30
- Start-up Voltage(V): 60-500
Aperçu
The Felicity IVDM4224P1G3 is an off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVDM4224P1G3.
Spécifications complètes
Caractéristiques électriques
| Battery Type | Lead-acid or Lithium-ion |
|---|---|
| Battery Voltage Range(V) | 20-30 |
| Start-up Voltage(V) | 60-500 |
| PV Input Voltage Range(V) | 60-425 |
| Rated PV Input Voltage(V) | 300-425 |
| Output Type | L+N+PE |
| Rated Output Frequency | 50Hz/60Hz |
| Output Voltage Waveform | Pure Sine Wave |
| Total Current Harmonic Distortion THDi | <3% |
| Rated Input Frequency | 50Hz/60Hz |
| DC reverse polarity protection | Yes |
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short Circuit Protection | Yes |
| Thermal Protection | Yes |
| Overvoltage Load Drop Protection | Yes |
| DC Component Monitoring | Yes |
| Monitor Mode | WIFI/LAN (Optional) |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC), OVC III (AC) |
Caractéristiques mécaniques
| Net Weight | 8.3kg |
|---|---|
| Gross Weight | 10.3kg |
| Product Dimension | 403x313x137mm |
| Package Dimension | 495x405x227mm |
Caractéristiques environnementales
| Operating Temperature Range | -40 to +60°C, >45°C Derating |
|---|---|
| Ingress Protection (IP) Rating | IP6X |
| Type of Cooling | Intelligent Air Cooling |
Certifications
- IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 N
Produits Connexes


AI100-5048 ESS
- Rated Output Power:5000VA
- Max. Solar Charging Current:100A

Felicity IVAM10048P1G1 10000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60

Felicity IVAM12048P1G1 12000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60
Articles Connexes
Batterie Felicity ne charge pas ? Codes et solutions
Batterie Felicity qui ne charge pas ? Sous 0°C le BMS bloque la charge, une tension sous 57,6 V ne remplit jamais le pack, et les codes C01–C08 font le reste.
Lire: Batterie Felicity ne charge pas ? Codes et solutions →Erreur onduleur Felicity après une coupure de courant ?
Une longue coupure a vidé la batterie, le réseau est revenu instable, et un code s'affiche. Le vrai sens de 04, C02, 27 et des alarmes réseau au retour.
Lire: Erreur onduleur Felicity après une coupure de courant ? →Onduleur Felicity en surchauffe ? Erreur 18 et codes chaleur
L'onduleur coupe l'après-midi ? Erreur 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 et C09 batterie — les codes chaleur officiels Felicity et leurs solutions.
Lire: Onduleur Felicity en surchauffe ? Erreur 18 et codes chaleur →