FAULT: LED1=OFF, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)
BMS Temperature Low.
FAULT: LED1=OFF, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)BMS Temperature Low.Défaut
BMS / electronics under-temperature protection has tripped.
Ambient temperature below the BMS operating range.
Move the battery to a warmer environment; do not operate below 0 degC for charging. Allow the BMS to warm before resuming use.
Felicitysolar LPBF24200-M LiFePO4 Battery System for Households User Guide.pdf · page 9FAULT: LED1=OFF, LED2=OFF, LED3=OFF, LED4=ON (Green OFF, Red ON)BMS Temperature Low.Défaut
BMS / electronics under-temperature protection has tripped. Listed in the FAULT row of the LED table on page 7 as 'BMS TEMPERATURE LOW'.
Ambient temperature below the BMS operating range. Section 1.3 item 14 forbids installation below 0 degC.
Move the battery to a warmer environment; do not install or operate below 0 degC. Allow the BMS to warm into the 0-45 degC operating range (section 3.2) before resuming use.
Battery Manual LPBF48250 (EN).pdf · page 7Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.