Défaut

F53

PV parallel failure.

3 Appareils signalant ce code
Apollo-5KLP1G01-MXSystème de stockage d’énergie↗ voir sur l’appareil
F53PV parallel failure.Défaut
Description

PV parallel failure; PV1 and PV2 paralleling configuration mismatch.

Cause

PV1 and PV2 paralleling configuration mismatch.

Correction recommandée

Please confirm whether PV1 and PV2 need to be set to parallel mode. if not, please turn off this function in APP. if necessary, please confirm whether the wiring of PV1 and PV2 is connected to parallel mode.

Source:Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf · page 44
F53PV parallel failure.Défaut
Description

PV parallel mode operation failure.

Correction recommandée

Please confirm whether PV1 and PV2 need to be set to parallel mode. if not, please turn off this function in APP. if necessary, please confirm whether the wiring of PV1 and PV2 is connected to parallel mode.

Source:T-REX-10KHP3G01-Inverter-User-Guide.pdf · page 29
F53Grid Over-frequency Fault.Défaut
Description

The grid frequency is too high, check whether the grid frequency is within the normal range.

Source:T-REX-50KHP3G01-user-manual-.pdf · page 47