Felicity MJS Solar Solutions

Felicity IVCM2012/IVCM3224P1G2

Discover the Felicity Solar IVCM2012P1G2 Inverter with 2000VA/2000W power and pure sine wave output for efficient energy conversion.

Models Covered: IVCM2012P1G2, IVCM3224P1G2

Manufacturer: Shenzhen Felicity Solar Technology Co., Ltd.

Application: The Felicity Solar IVCM P1G2 Series Inverter is engineered for optimal performance, delivering a robust 2000VA/2000W power output. With a nominal output voltage of 230Vac and pure sine wave technology, this inverter ensures efficient and reliable energy conversion for your solar power systems.

Technical Specifications

Technical Specifications
Parameter IVCM2012P1G2IVCM3224P1G2
Electrical Characteristics
High DC Input Recovery 14.5V29V
Output Short Circuit Protection 165ABattery mode: Electronic Circuit Max Discharge current 135A
Additional Specifications
Input Voltage Range 90-280Vac Surge Rating
Input Voltage waveform Sinusoidal (utility or generator)
Nominal Input Frequency 50Hz/ 60HZ Self - defined
Over Charge Protection Yes Low Battery Alarm
Range Storage Temperature -15°C -60°С
Charge Current Regulation 0~120A (Adj 5A) Cold Start Voltage 21.oV
Nominal Input Voltage 230Vac Over-Load Protection (SMPS load)
Transfer Time (Single unit) ms typical (UPS); 20ms typical (Apliances Output Voltage Waveform
AC Output
Rated Output Power 2000VA/2000W3200VA/3200W
Nominal Output Voltage 230Vac
Output Voltage Waveform Pure sine wave
Nominal Output Frequency (Hz) 50±0.3Hz/60±0.3Hz
Peak Efficiency 90%93%
Battery Input
Nominal DC Input Voltage 12V24V
Max Discharge Current 165A135A
PV Input
Max PV Open Circuit Voltage 105V
MPPT Voltage Range 30~90V30-90V @Load ≥ 50% 20.2V
Max Input Power 800W1600W
Mechanical Data
Package Dimension (D*W*H) 438x358x202mm
Net Weight (kg) 6.5kg
Product Size (D*W*H) 356x272x118mm
Operating Conditions
Operating Temperature -10°C-55°С
Storage Temperature -15°C ~60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Pure sine wave inverter: Pure sine wave inverter
  • Built-in MPPT solar charging: controller with an efficiency of 99%
  • Configurable input voltage range: for home appliances and personal computers
  • Compatible to mains voltage: or generator power
  • Cold start function: Cold start function
  • Supports silent mode: Supports silent mode

Frequently Asked Questions

What are the main performance specifications of the IVCM P1G2 Series inverter?

The IVCM P1G2 Series inverter has a rated output power of 2000VA/2000W and operates at a nominal output voltage of 230Vac. It delivers a pure sine wave output with a peak efficiency of 90%.

Is the IVCM P1G2 Series inverter compatible with my solar panel system?

The inverter is compatible with solar panel systems that have a nominal DC input voltage of 12V and a maximum PV open circuit voltage of 105V. It supports an MPPT voltage range of 30~90V.

What are the physical specifications of the IVCM P1G2 Series inverter?

The inverter measures 356x272x118mm and weighs 6.5kg. It is designed to be compact and lightweight for easy installation.

What are the installation requirements for the IVCM P1G2 Series inverter?

The inverter should be installed in an environment with temperatures ranging from -10°C to 55°C. Ensure proper ventilation and avoid exposure to direct sunlight or moisture.