Felicity IVGM25KHP3G3
The Felicity IVGM25KHP3G3 is a hybrid inverter with specifications as published by the manufacturer.
Technical Specifications
| Parameter | IVGM25KHP3G3 |
|---|---|
| Battery Data | |
| Supported Battery Type | LFP (LiFePO4) |
| Battery Voltage Range | 160~700Vdc |
| Additional Specifications | |
| Max. Charging Current | 50(A) |
| Max. Discharging Current | 50(A) |
| Max. DC Input Power | 40kW |
| AC Wiring Mode | 3L+N+PE |
| DC Injection Current | <0.5% In |
| PV String Input Data | |
| Max PV Input Power | 50kW |
| Max PV / DC Voltage | 1000Vdc |
| Min DC Input Voltage | 150Vdc |
| Start-up Voltage | 200Vdc |
| Nominal DC Voltage | 600Vdc |
| MPPT Voltage Range | 200~850Vdc |
| MPPT Voltage Range at Full Load | 666-850Vdc |
| Max PV Input Current | 30+30(A) |
| Max PV Short-Circuit Current | 39+39(A) |
| Strings per MPP Tracker | 2+2 |
| Electrical / AC Output Data | |
| Rated AC Power | 25kW |
| Max AC Apparent Power | 27.5kVA |
| Rated AC Output Current | 36.3A |
| Max AC Output Current | 39.8A |
| Peak Power (with duration) | 1.5times of |
| Nominal AC Voltage | 220/380,230/400 Vac (-20%~+15%) |
| Grid / AC Frequency | 50/60 Hz (45~55 Hz/55~65 Hz) |
| THD / THDi | <3% (At |
| Power Factor | 0.8( leading) to 0.8( lagging) |
| Communication | |
| Monitoring Module | WiFi/4G |
| Mechanical Data | |
| Net Weight | 41.4KG |
| Gross Weight | 47.4KG |
| Dimensions (W×H×D) | 642*445*237.5MM |
| Package Dimensions | 784*563*367MM |
| Installation / Mounting | Wall-mounted |
| Protection Features | |
| IP Rating | IP66 |
| Operating Conditions | |
| Operating Temperature | -40 to 60°C(>45°C Derating) |
| Relative Humidity | 0~95% (No Condensation) |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.