Felicity Solar IVGM5KLP1G1
The Felicity IVGM5KLP1G1 is a hybrid inverter with a 360V nominal bus, 5000VA/5000W rated output. Every figure on this page is taken from the manufacturer's dat
Download PDF Datasheet WhatsApp UsTechnical Specifications
| Parameter | IVGM5KLP1G1 |
|---|---|
| PV String Input Data | |
| Max Recommended PV Power | 6500W (3500W for Single PV) |
| Max PV / DC Voltage | 550V Start Oltage 130V |
| MPPT Voltage Range | 100V-500V |
| MPPT Voltage Range at Full Load | 220V-500V |
| Number of MPP Trackers | 2/1 |
| PV Operating Voltage Range | 90V-550V |
| Strings per MPP Tracker | 2/1 |
| Max PV Short-Circuit Current | 18A/18A |
| Nominal DC Voltage | 360V |
| Electrical / AC Output Data | |
| Max AC Output Power | 5000W |
| Rated Apparent Power | 5000VA/5000W |
| AC Input Voltage | 230Vac |
| AC Output Voltage | 230Vac |
| Grid / AC Frequency | 50/60Hz |
| Max AC Output Current | 30A |
| Output Frequency | 50/60Hz |
| Rated AC Output Current | 21.7A |
| THD / THDi | <3% |
| Max AC Input Current | 40A |
| Max Continuous AC Pass-Through | 40A |
| Power Factor | >0.99 |
| Battery Data | |
| Battery Voltage Range | 40V~60V |
| Continuous Charge/Discharge Power | 5000W |
| Max Charge Current | 100A |
| Max Charge/Discharge Current | 100A/100A |
| Protection Features | |
| IP Rating | IP65 |
| Safety / EMC Standards | IEC 62109-1/-2 EMC IEC/EN 61000-6-1/2/3/4 EN/IEC 61000-3-11/12 |
| Mechanical Data | |
| Cooling | Nature |
| Dimensions (W×H×D) | 530*493*228MM |
| Gross Weight | 39.1KG |
| Installation / Mounting | Wall-mounted |
| Net Weight | 32.4KG |
| Package Dimensions | 632*570*315MM ME |
| Operating Conditions | |
| Operating Temperature | -25°C~60°C, -45°C Derating |
| Communication | |
| BMS Communication | CAN/RS485 |
Note: Specifications are based on the official Felicity Solar IVGM5KLP1G1 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Availability & grid compliance in Oman
| Market | Oman |
| Grid authority / regulator | Authority for Electricity Regulation Oman |
| Quotation currency | OMR |
| Support hours timezone | Asia/Muscat |
| Delivery & installation coverage | Muscat, Salalah, Sohar |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Oman that is Authority for Electricity Regulation Oman. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.