Technical Specifications

Technical Specifications
Parameter IVAM8048P1G1
PV String Input Data
Max PV Input Power 16000 W
Max PV Input / Array Open Circuit Voltage 500 V
Max PV Input Current 27+27 A
MPP Trackers / Strings per Tracker 2/2+2
MPPT Voltage Range 90~425 V
MPPT Voltage Range at Full Load 200~425 V
Number of MPP Trackers 2/2+2
PV Operating Voltage Range 90~500 V
Start-up Voltage 120 V
Max PV Short-Circuit Current 40+40 A
MPPT Nominal Voltage 370 V
Electrical / AC Output Data
Max AC Output Power 8000 W
Peak Power (with duration) 2 times of rated power, 10s
Rated AC Power 8000 W
AC Frequency Range 50Hz/60Hz
AC Input Voltage 230 V
Nominal AC Voltage 230 V
Output Frequency 50Hz/60Hz
Output Waveform Pure Sine Wave
THD / THDi <3%
Max AC Output Current 34.8 A
Max Grid Input Current 50 A
Battery Data
Battery Voltage Range 40~60 V
Max Charge Current 190 A
Max Charge Power 8000 W
Max Discharge Current 190 A
Supported Battery Type Lead-acid or Lithium-ion
Number of Battery Inputs 1

Note: Specifications are based on the official Felicity Solar IVAM8048P1G1 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Lebanon

Market Lebanon
Grid authority / regulator EDL Lebanon
Quotation currency LBP
Support hours timezone Asia/Beirut
Delivery & installation coverage Beirut, Tripoli, Sidon

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Lebanon that is EDL Lebanon. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.