Technical Specifications
| Parameter | IVPS7548 |
|---|---|
| Additional Specifications | |
| Capable of Starting Electric | Yes |
| Input Voltage Range | 90-280Vac |
| Nominal Input Voltage | 220Vac |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Re-connect | 270±7Vac |
| Max AC Input Voltage | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz |
| Low Line Frequency Re-connect | 42±1Hz |
| High Line Frequency Disconnect | 65±1Hz |
| High Line Frequency Re-connect | 63±1Hz |
| Pass Through Without Battery | No |
| Over Charge Protection | Yes |
| Capable of Starting Electric Motor | Yes |
| Output Short Circuit Protection | Yes |
| Electrical Data | |
| Efficiency (Line mode) | ≥95% (rated R load, battery fully charged) |
| Max Bypass Overload Current | AC 63A |
| Low Battery Alarm | 46V (load < 50%) / 44V (load ≥ 50%) |
| High DC Input Alarm / Fault | 63±0.4V |
| Electrical Characteristics | |
| Over-Load Protection (SMPS load) | Air switch protection |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) |
| High Line Disconnect | 280±7Vac |
| Transfer Time (AC to DC) | 15ms (typical) |
| Max Charge Current | 60A |
| Charge Current Regulation | 0A~60A |
| Charger Short Circuit | AC 63A |
| Output Voltage Waveform | Pure sine wave |
| Over-Load Protection | 5s@≥150% load; 10s@105%~150% load SMPS load |
| Surge Rating | 15000VA for 5 seconds |
| Cold Start Voltage | 46V |
| Low Battery Recovery | 47V (load < 50%) / 46V (load ≥ 50%) |
| Low DC Input Shut-down | 43V (load < 50%) / 42V (load ≥ 50%) |
| High DC Input Recovery | 62±0.4V |
| Boost Charging Voltage (AGM) | 57.6V |
| Float Charging Voltage (AGM) | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V |
| AC Output | |
| Rated Output Power (VA) | 7500VA |
| Rated Output Power (W) | 6000W |
| Nominal Output Voltage | 220Vac±5% |
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) |
| Output Voltage Regulation | ±5%rms |
| Peak Efficiency | 90% |
| DC Input | |
| Nominal DC Input Voltage | 48V |
| Battery Charging | |
| Max Charging Current (Utility + Solar) | 170A | 180A | 200A |
| Mechanical Data | |
| Package Dimension | 607x540x290mm |
| Operating Conditions | |
| Operating Temperature | 0°C-40°C |
| Storage Temperature | -15°C~60°C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Jordan
| Market | Jordan |
| Grid authority / regulator | EMRC Jordan |
| Quotation currency | JOD |
| Support hours timezone | Asia/Amman |
| Delivery & installation coverage | Amman, Zarqa, Irbid |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Jordan that is EMRC Jordan. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Bypass charging function: Bypass charging function
- High charging current: High charging current
- Wide range of AC: input voltage
- 50/60Hz compatible: 50/60Hz compatible
- Intelligent adjustment of over-discharge: voltage
- Comprehensive protection features: Comprehensive protection features
Frequently Asked Questions
What are the main performance specifications of the IVPS/IVPM Series inverter?
The IVPS/IVPM Series inverter has a rated output power of 2500VA and 2000W. It offers a nominal output voltage of 220Vac and operates at a frequency of 50±0.3Hz or 60±0.3Hz, which is adjustable. The inverter achieves a peak efficiency of 90%.
Is the IVPS/IVPM Series inverter compatible with my solar setup?
Yes, the inverter is designed to work with a nominal DC input voltage of 12V and can handle a maximum charging current of 170A from both utility and solar sources, making it compatible with most standard solar setups.
What are the physical specifications of the IVPS/IVPM Series inverter?
The inverter has package dimensions of 552x408x290mm. Please refer to the product manual for weight and IP rating details.
What are the installation requirements for the IVPS/IVPM Series inverter?
The inverter should be installed in an environment with an operating temperature between 0°C and 40°C. Ensure proper ventilation and follow the installation guidelines provided in the manual for optimal performance.