Felicity Solar IVDM4224P1G3

The Felicity IVDM4224P1G3 is a off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer'

Models Covered: IVDM4224P1G3

Manufacturer: Felicity Solar

Application: The Felicity IVDM4224P1G3 is a off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVDM4224P1G3.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter IVDM4224P1G3
PV String Input Data
PV Operating Voltage Range 60 V – 425 V
Start-up Voltage 60-500 V
MPPT Nominal Voltage 300-425 V
Electrical / AC Output Data
AC Frequency Range 50Hz/60Hz
Output Frequency 50Hz/60Hz
Output Waveform Pure Sine Wave
THD / THDi <3%
Output Type L+N+PE
Topology Non-Isolated
Battery Data
Battery Voltage Range 20 V – 30 V
Supported Battery Type Lead-acid or Lithium-ion
Protection Features
IP Rating IP6X
AC Short-Circuit Protection Yes
DC Component Monitoring Yes
DC Reverse Polarity Protection Yes
Over-Current Protection Yes
Over-Temperature / Thermal Protection Yes
Over-Voltage Protection Yes
Overload Protection Yes
Overvoltage Category OVC II(DC), OVC III (AC)
Mechanical Data
Cooling Method Intelligent Air Cooling
Dimensions (W×H×D) 403x313x137mm
Gross Weight 10.3kg
Net Weight 8.3kg
Package Dimensions 495x405x227mm
Operating Conditions
Operating Temperature -40 to +60°C, >45°C Derating
Communication
Monitoring Module WIFI/LAN (Optional)

Note: Specifications are based on the official Felicity Solar IVDM4224P1G3 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Italy

Market Italy
Grid authority / regulator ARERA Italy
Quotation currency EUR
Support hours timezone Europe/Rome
Delivery & installation coverage Rome, Milan, Naples, Turin

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Italy that is ARERA Italy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.