Felicity Solar FLH96050SG2/FLH96050SG2-H

The Felicity FLH96050SG2/FLH96050SG2-H is a battery with 10.24kWh 15.36kWh 20.48kWh 25.6kWh 30.72kWh of usable storage, > 6000 Cycles rated. Every figure on thi

Models Covered: FLH96050SG2/FLH96050SG2-H

Manufacturer: Felicity Solar

Application: The Felicity FLH96050SG2/FLH96050SG2-H is a battery with 10.24kWh 15.36kWh 20.48kWh 25.6kWh 30.72kWh of usable storage, > 6000 Cycles rated. Every figure on this page is taken from the manufacturer's datasheet for the FLH96050SG2/FLH96050SG2-H.

Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter FLH96050SG2/FLH96050SG2-H
Electrical / AC Output Data
Operating Voltage Range 185.6-230.4V 278.4-345.6V 371.2-460.8V 464-576V 556.8-691.2V
System Nominal Voltage 204.8V 307.2V 409.6V 512V 614.4V
Module Nominal Voltage 102.4V
Battery Data
System Energy 10.24kWh 15.36kWh 20.48kWh 25.6kWh 30.72kWh
Usable Energy 9.21kWh 13.82kWh 18.43kWh 23.04kWh 27.64kWh
Cycle Life > 6000 Cycles
Depth of Discharge 90%
Max Charge/Discharge Current 50A 50A 50A 50A 50A
Module Capacity 50Ah
Module Energy 5.12kWh
Battery Designation IFPP/41/150/102/[(1P32S) NS] M/-10+50/90
Protection Features
IP Rating IP65 Charge: 0°C~+55 °C
Mechanical Data
Dimensions (W×H×D) 600x385x260MM
Gross Weight 24.5KG FLH96050SCG2 FLH96050SCG2-H 600x385x200MM
Net Weight 57.5KG FLH96050SMG2
Package Dimensions 712x497x352MM
Operating Conditions
Max Altitude < 2000M
Operating Temperature Discharge: -20°C~+55 °C
Relative Humidity 5%~95%
Storage Temperature Range 0°C~+35°C

Note: Specifications are based on the official Felicity Solar FLH96050SG2/FLH96050SG2-H datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.

Availability & grid compliance in UAE

Market UAE
Grid authority / regulator DEWA, ADDC, SEWA
Quotation currency AED
Support hours timezone Asia/Dubai
Delivery & installation coverage Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Availability & grid compliance in Italy

Market Italy
Grid authority / regulator ARERA Italy
Quotation currency EUR
Support hours timezone Europe/Rome
Delivery & installation coverage Rome, Milan, Naples, Turin

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Italy that is ARERA Italy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.