Felicity IVPS5048
Discover Felicity Solar's IVPS/IVPM Series Inverters with 2500VA/2000W output, 220Vac voltage, and 12V DC input for efficient energy conversion.
Technical Specifications
| Parameter | IVPS5048 |
|---|---|
| Additional Specifications | |
| Capable of Starting Electric | Yes |
| Input Voltage Range | 90-280Vac |
| Nominal Input Voltage | 220Vac |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Re-connect | 270±7Vac |
| Nominal Input Frequency | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz |
| Low Line Frequency Re-connect | 42±1Hz |
| High Line Frequency Disconnect | 65±1Hz |
| High Line Frequency Re-connect | 63±1Hz |
| Pass Through Without Battery | No |
| Capable of Starting Electric Motor | Yes |
| Output Short Circuit Protection | Yes |
| Electrical Data | |
| Efficiency (Line mode) | ≥95% (rated R load, battery fully charged) |
| Max AC Input Voltage | 280Vrms |
| Max Bypass Overload Current | AC 63A |
| Over-Charge Protection | Yes |
| Electrical Characteristics | |
| Over-Load Protection (SMPS load) | Air switch protection |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) |
| High Line Disconnect | 280±7Vac |
| Transfer Time (AC to DC) | 15ms (typical) |
| Transfer Time (DC to AC) | 15ms (typical) |
| Input Voltage Range (utility charge) | 90~280Vac |
| Max Charge Current | 50A |
| Charge Current Regulation | 0A~50A |
| Charger Short Circuit | AC 63A |
| Output Voltage Waveform | Pure sine wave |
| Over-Load Protection | 5s@≥150% load; 10s@105%~150% load SMPS load |
| Surge Rating | 10000VA for 5 seconds |
| Cold Start Voltage | 46V |
| Low Battery Recovery | 47V (load < 50%) / 46V (load ≥ 50%) |
| Low DC Input Shut-down | 43V (load < 50%) / 42V (load ≥ 50%) |
| High DC Input Recovery | 62±0.4V |
| Boost Charging Voltage (AGM) | 57.6V |
| Float Charging Voltage (AGM) | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V |
| AC Output | |
| Rated Output Power (VA) | 5000VA |
| Rated Output Power (W) | 4000W |
| Nominal Output Voltage | 220Vac±5% |
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) |
| Output Voltage Regulation | ±5%rms |
| Peak Efficiency | 90% |
| DC Input | |
| Nominal DC Input Voltage | 48V |
| Battery Charging | |
| Max Charging Current (Utility + Solar) | 170A | 180A | 200A |
| Mechanical Data | |
| Package Dimension | 607x540x290mm |
| Operating Conditions | |
| Operating temperature | 0°C~40°C |
| Storage Temperature | -15°C~60°C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Bypass charging function: Bypass charging function
- High charging current: High charging current
- Wide range of AC: input voltage
- 50/60HZ compatible: 50/60HZ compatible
- Intelligent adjustment of over-discharge: voltage
- Comprehensive protection features: Comprehensive protection features
Frequently Asked Questions
What are the main performance specifications of the IVPS/IVPM Series inverter?
The IVPS/IVPM Series inverter has a rated output power of 2500VA and 2000W, with a nominal output voltage of 220Vac. It operates at a nominal frequency of 50±0.3Hz or 60±0.3Hz, and offers a peak efficiency of 90%.
Is the IVPS/IVPM Series inverter compatible with generators?
Yes, the IVPS/IVPM Series inverter is compatible with generators as it accepts a sinusoidal input voltage waveform from utility or generator sources.
What are the physical specifications of the IVPS/IVPM Series inverter?
The IVPS/IVPM Series inverter has package dimensions of 552x408x290mm. Please note that the weight and IP rating are not specified in the provided information.
What are the installation requirements for the IVPS/IVPM Series inverter?
The inverter should be installed in an environment with an operating temperature range of 0°C to 40°C. Ensure proper ventilation and follow all safety guidelines during installation.