Felicity MJS Solar Solutions

Felicity IVPS10048

Discover Felicity Solar IVPS/IVPM Series Inverters with 2500VA/2000W output, 220Vac voltage, and 40A max charging current.

Models Covered: IVPS10048

Manufacturer: Shenzhen Felicity Solar Technology Co., Ltd.

Application: Introducing the Felicity Solar IVPS/IVPM Series Inverters, designed to deliver reliable power with a rated output of 2500VA/2000W. With a nominal output voltage of 220Vac and a maximum charging current of 40A, these inverters are perfect for efficient energy management.

Technical Specifications

Technical Specifications
Parameter IVPS10048
Additional Specifications
Capable of Starting Electric Yes
Input Voltage Range 90-280Vac
Nominal Input Voltage 220Vac
Low Line Re-connect AC Input Range 180±7Vac (UPS) / 100±7Vac (APL)
High Line Re-connect 270±7Vac
Max AC Input Voltage 280Vrms
Nominal Input Frequency 50Hz/60Hz
Low Line Frequency Disconnect 40±1Hz
Low Line Frequency Re-connect 42±1Hz
High Line Frequency Disconnect 65±1Hz
High Line Frequency Re-connect 63±1Hz
Pass Through Without Battery No
Over Charge Protection Yes
Capable of Starting Electric Motor Yes
Output Short Circuit Protection Yes
Electrical Data
Efficiency (Line mode) ≥95% (rated R load, battery fully charged)
Max Bypass Overload Current AC 63A
Low Battery Alarm 46V (load < 50%) / 44V (load ≥ 50%)
High DC Input Alarm / Fault 63±0.4V
Electrical Characteristics
Over-Load Protection (SMPS load) Air switch protection
Input Voltage Waveform Sinusoidal (utility or generator)
Low Line Disconnect 170±7Vac (UPS) / 90±7Vac (APL)
High Line Disconnect 280±7Vac
Transfer Time (AC to DC) 15ms (typical)
Max Charging Current (Utility + Solar) 80A
Charge Current Regulation 0A~80A
Charger Short Circuit AC 63A
Output Voltage Waveform Pure sine wave
Over-Load Protection 5s@≥150% load; 10s@105%~150% load SMPS load
Surge Rating 20000VA for 5 seconds
Cold Start Voltage 46V
Low Battery Recovery 47V (load < 50%) / 46V (load ≥ 50%)
Low DC Input Shut-down 43V (load < 50%) / 42V (load ≥ 50%)
High DC Input Recovery 62±0.4V
Boost Charging Voltage (AGM) 57.6V
Float Charging Voltage (AGM) 54.4V
Boost Charging Voltage (Flooded) 58.4V
Float Charging Voltage (Flooded) 55.2V
Self-Defined Charging Voltage (max) 61.0V
AC Output
Rated Output Power (VA) 10000VA
Rated Output Power (W) 8000W
Nominal Output Voltage 220Vac±5%
Nominal Output Frequency (Hz) 50±0.3Hz / 60±0.3Hz (adjustable)
Output Voltage Regulation ±5%rms
Peak Efficiency 90%
DC Input
Nominal DC Input Voltage 48V
Mechanical Data
Package Dimension 670x470x355mm
Operating Conditions
Operating temperature 0°C-40°C
Storage Temperature -15°C~60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Bahrain

Market Bahrain
Grid authority / regulator EWA Bahrain
Quotation currency BHD
Support hours timezone Asia/Bahrain
Delivery & installation coverage Manama, Riffa, Muharraq

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Bahrain that is EWA Bahrain. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Bypass charging function: Bypass charging function
  • High charging current: High charging current
  • Wide range of AC: input voltage
  • 50/60Hz compatible: 50/60Hz compatible
  • Intelligent adjustment of over-discharge: voltage
  • Comprehensive protection features: Comprehensive protection features

Frequently Asked Questions

What are the main performance specifications of the IVPS/IVPM Series inverter?

The IVPS/IVPM Series inverter has a rated output power of 2500VA and 2000W, with a nominal output voltage of 220Vac. It operates at a nominal frequency of 50Hz/60Hz±0.3Hz and achieves a peak efficiency of 90%.

Is the IVPS/IVPM Series inverter compatible with my solar setup?

The inverter is compatible with systems that have a nominal DC input voltage of 12V and can handle a maximum charging current of 40A from both utility and solar sources.

What are the physical specifications of the IVPS/IVPM Series inverter?

The inverter has package dimensions of 552x408x290mm. Please refer to the product manual for weight and IP rating details.

What are the installation requirements for the IVPS/IVPM Series inverter?

Ensure the inverter is installed in an environment with an operating temperature between 0°C and 40°C. Proper ventilation and adherence to installation guidelines in the manual are crucial.